User manual DPC Touch V2
DOC.60352-11/20
89
8.3 Modbus TCP/IP addresses
Adr.
Operation
Description
Function Code
1
Tool selection
2: GX/GY/DO/GA
3: DC Tools
0x03/0x06
2
Screws counting up
0: Not use 1: Use
0x03/0x06
3
Screw counting for step
0: Not use 1: Use
0x03/0x06
4
Torque selection by binary outputs
0: Not use 1: Use
0x03/0x06
5
Job selection by binary inputs
0: Not use 1: Use
0x03/0x06
6
Default job number
value = Job no
0x03/0x06
7
Skip button access without password
0: Not use 1: Use
0x03/0x06
8
Back button access without password
0: Not use 1: Use
0x03/0x06
9
Reset button access without password
0: Not use 1: Use
0x03/0x06
10 Job selection access without password
0: Not use 1: Use
0x03/0x06
11 Display job reset button
0: Not use 1: Use
0x03/0x06
12 Min fastening time limit %
value <= 25
0x03/0x06
13 Max fastening time limit %
value <= 25
0x03/0x06
14 Start trigger release time limit(ms)
value <= 9999
0x03/0x06
15 Temporary position loss time(ms)
value <= 3000
0x03/0x06
16 Judge Time(ms)
value <= 500
0x03/0x06
17 Number of retightening on a position
value <= 9
0x03/0x06
18 Skip NG tightening
0: Not use 1: Use
0x03/0x06
19 Fastening NG signal if position skipped
0: Not use 1: Use
0x03/0x06
20 Auto reset delay(ms)
value <= 9999
0x03/0x06
21
Automatically restart the job when
finished
0: Not use 1: Use
0x03/0x06
22 Store logs during operation
0: Not use 1: Use
0x03/0x06
23 Skip by step
0: Not use 1: Use
0x03/0x06