User manual DPC Touch V2
DOC.60352-11/20
79
Input/O
utput
Assigned
signal
DB44
N° pin
DB25
N° pin
Input/
Output
Signal
Output 1 Torque Select 1
16
1
Input 1
Select program
1
Output 2 Torque Select 2
17
2
Input 2
Select program
2
Output 3 Torque Select 3
18
3
Input 3
Select program
3
Output 4 Torque Select 4
19
4
Input 4
Select program
3
Output 5 Tool Disable
20
5
Input 5
Driver lock
Input 1
Driver Run
1
10
Output 1 Motor Run
Input 2
Tool Alarm
2
11
Output 2 Alarm
Input 3
Driver Torque up
3
12
Output 3 Fastening OK
IN_COM
14, 15
22
0V DC
OUT_COM
29, 30
21
24V DC
Information
All 8 inputs and 8 outputs of MDC controller are wired to DPC Touch
controller. These signals can be used for advanced functions
(management of Reset, Reverse, etc). I/O’s numbers are matching.
Assign signals on DPC Touch and MDC as above.
Select DC tool interface in DPC Touch operating settings.
Activate Torque selection by binary in DPC Touch operating settings.