User manual DPC Touch V2
DOC.60352-11/20
32
Torque
select 1-8
Signals to select fastening presets on the tool in
binary or direct logic (see the table below). Logic is
selected in operating settings.
Continuous
Job OK
Signal is provided after successful completion of a
job.
Impulse
Job NG
Signal is provided after if a job was interrupted or
completed with missing screws.
Impulse
System ready
Signal is provided when the controller is in operating
mode and ready for selection of jobs. Once a job is
started the signal drops down.
Continuous
Alarm
Signal is provided when the controller is in Alarm
mode
Continuous
The table below shows the relation between Torque select signals and Preset
number in direct logic.
Job Number
Torque
select 1
Torque
select 2
Torque
select 3
…
Torque
select 8
0
1
0
0
0
0
1
0
1
0
0
0
2
0
0
1
0
0
…
8
0
0
0
0
1