DMF series - Torque reaction arms
60353-12/20
25
2.4.9 Balancing kit installation
Install the balancer by firmly tightening the mounting bolt. Use the spacer
provided to properly align the balancer. Use of the lock nut allows the balancer
to rotation. Make sure the balancer cable is parallel with the arm.
Kit DMF 5 / 12
Kit DMF 30 & more
Kit for DMFi
Warning
Between the balancer and the frame, install the included safety
cable to avoid falling. Refer to the dedicated user manual of your
balancing model.
2.4.10 Encoders verification (LPC, LAPC series)
For LAPC models, connect the encoder cable to the encoder junction box.
Then connect the DB9 cable from the junction box to the DOGA position
control system (DPC Touch V2).
For LPC models, directly connect the DB9 encoder cable to the DOGA
position control system (DPC Touch V2).