DMF series - Torque reaction arms
60353-12/20
22
2.4.5 Clamp mounting for DMFi 70/120/200/300
Mounting a clamp requires the removal of the axis (1). To do so, unscrew the
two locking screws (2). Remove the axis (1) from its housing to mount the
clamp (3). Then replace the axis. Retighten the locking screws (2) using
medium threadlocker.
Warning
Ensure the tightening of the clamp axis to prevent accidental tool
disengagement and possible operator injury.
(1)
(2)
(2)
(3)
(4)