User manual 250/400 OLED
Rev.: SG-20220516
Page 49 of 79
FlexxPump 250 / 400 OLED
User manual
Changing the emptying time t
EZ
:
As soon as the Settings menu has been selected, the active operating mode is displayed. To be able
to set the emptying time t
EZ
, the operating mode Setting emptying time with the calendar symbol must
be selected. If this is not the case, change the operating mode accordingly. An explanation of how to
change the operating mode can be found in Chap. 6.3.4.
After the display of the operating mode Setting emptying time, the emptying time t
EZ
in months and
the number of lubrication strokes C per pumping cycle PZ can be set; a direct entry to the number of
lubrication strokes C is not possible.
In addition to the display of the active operating mode, the confirmation hook appears; the display
and the hook flash twice for visual confirmation.
In the next step, the currently set value of the emptying time (t
EZ actual
) is shown in the display. You
now have the option of changing the value.
Changing a value of the emptying time t
EZ
:
If you want to change the value of the emptying time t
EZ
, move the activation and programming key to
the action area again.
The double circle appears and the next higher (t
EZ 1
) adjustable value of the emptying time is
shown in the display. The double circle lights up as long as the activation and programming key is on the
action surface; the other values of the emptying time run through one after the other. However, you can
also remove the activation and programming key from the action surface and shortly afterwards return it
to the action surface in order to reach each value individually one after the other. If the final value of the
emptying time of t
EZ
= 36 is reached and no value was selected, the menu jumps back to t
EZ
= 01 and the
run can be started again.
When the new value you desire for the emptying time (t
EZ new
) is shown in the display, remove the
activation and programming key from the action surface.
The confirmation hook appears; for visual confirmation, the display and the hook flash twice. The
selected new value (t
EZ new
=> t
EZ actual
) of the emptying time has now been accepted. The submenu now
automatically takes you to the values for the number of lubrication strokes C.
No changing a value of the emptying time t
EZ
:
If you do not want to change the value of the emptying time t
EZ
, the activation and programming key
must remain away from the action area.
The confirmation hook appears; for visual confirmation, the display and the hook flash twice, while
the display shows the emptying time t
EZ
. The submenu now automatically continues to the values of the
number of lubrication strokes C.
The display first shows the currently set value for the number of lubrication strokes per pump cycle
(C
actual
). You now have the option of changing the values.