Procedure:
The FP 250/400 OLED is switched on and there is no fault or error.
Remove the activation and programming key from the upper housing of the FP 250/400 OLED and
place it on the action area.
Hold the activation and programming key on the action area. The double circle appears in the bottom
right corner. Leave the activation and programming key on the action area until
Settings
appears in
the display. Remove the activation and programming key from the action area until Settings appears in
the display. The double circle disappears.
The confirmation hook appears; the display and the hook flash twice for visual confirmation.
The Settings menu allows changing specific parameters of the selected operating mode. This chapter
explains the parameters essential for the operating mode Setting lubrication cycle duration and how
you can change the specific parameters Lubrication cycle duration t
SZ
in hours and the number of
lubrication strokes C per pump cycle PZ when the operating mode Setting lubrication cycle duration is
selected.
Performing changes: