![DLS FlexxPump 250 OLED User Manual Download Page 43](http://html1.mh-extra.com/html/dls/flexxpump-250-oled/flexxpump-250-oled_user-manual_2513552043.webp)
User manual 250/400 OLED
Rev.: SG-20220516
Page 42 of 79
FlexxPump 250 / 400 OLED
User manual
Changing the lubrication cycle duration t
SZ
:
As soon as the Settings menu has been selected, the active operating mode is displayed. To be able
to set the lubrication cycle duration t
SZ
, the operating mode Lubrication cycle duration setting must be
selected with the symbol of the dial. If this is not the case, change the operating mode accordingly. An
explanation of how to change the operating mode can be found in Chap. 6.3.4.
After the operating mode Setting lubrication cycle duration is displayed, the lubrication cycle duration
t
SZ
and then the number of lubrication strokes C can be set; direct access to the number of lubrication
strokes C is not possible.
In addition to the display of the active operating mode, the confirmation hook appears; the display
and the hook flash twice for visual confirmation.
In the next step, the currently set value of the lubrication cycle duration (t
SZ actual
) is shown in the display.
You now have the option of changing the value.
Changing a value of the lubrication cycle duration t
SZ
:
If you want to change the value of the lubrication cycle duration t
SZ
, move the activation and programming
key back to the action surface.
The double circle appears and the next higher (t
SZ 1
) adjustable value of the lubrication cycle
duration is shown in the display. The double circle lights up for as long as the magnet pin is on the action
surface; the other values of the lubrication cycle duration run through one after the other (the display
accelerates). However, you can also remove the activation and programming key from the action surface
and place it on the action surface again shortly afterwards in order to reach each value individually one
after the other. If the final value of the lubrication cycle duration of t
SZ
= 240 is reached and no value was
selected, the menu jumps back to t
SZ
= 01 and the run can be started again.
When the new value you desire for the lubrication cycle duration (t
SZ new
) is shown in the display,
remove the activation and programming key from the action surface.
The confirmation hook appears; for visual confirmation, the display and the hook flash twice. The
selected new value (t
SZ new
=> t
SZ actual
) of the lubrication cycle duration has now been accepted. The
submenu now automatically continues to the values of the number of lubrication strokes.
No changing a value of the lubrication cycle duration t
SZ
:
If you do not want to change the value of the lubrication cycle duration t
SZ
, the activation and
programming key must remain away from the action area.
The confirmation hook appears; for visual confirmation, the display and the hook flash twice, while
the display shows the lubrication cycle duration t
SZ
. The submenu now automatically continues to the
value of the number of lubrication strokes C.
The display first shows the currently set value for the number of lubrication strokes per pump cycle
(C
actual
). You now have the option of changing the values.