7.4 Zone Setting Page(s)

Each of the 4 zones within the DLM-4 Zone Controller has a separate 
page for that zone’s particular settings. The settings are described 
below.

Wattage: 

Select the wattage of ballast that will be connected to this 

zone. (Each zone can only have one type of ballast connected) Choose 
between 1000, 600 and 315 watts.

Output Max: 

Select the wattage that you would like to operate the 

fixtures in increments of 25 watts. The user can select any setting 
between 600 watts and 1150 watts for the 1000 watt fixture. For the 
600/750 fixture any setting between 400 watts and 825watts can 
be selected. (The 315 watt fixture is pre-set at 315 watts) Each zone 
can operate the fixtures connected to it at different power settings. 
When the lights are running normally (without dimming) this setting 
determines the wattage each zone will operate at.

*NOTE: 

The DLI 315 watt fixtures 

CANNOT 

be dimmed.

On at: 

This is the time of day that the lights for that zone will be turned 

ON.

Off at: 

This is the time of day that the lights for that zone will be turned 

OFF.

Dim at: 

The user can select the temperature that they want the 

lights within each zone to dim. Dimming the lights will reduce the 
heat-load within the growing area and lower the temperature within 
the growing area. The DLM-4 Zone Controller provides a gradual 
dimming from full power, down to approximately 60% power as the 
temperature rises above the user’s  “Dim At” setpoint. (Dimming occurs 
over a 5’F differential from the Dim At setpoint)

*NOTE: 

The 315 watt ballast cannot be dimmed. The 315 watt lights will 

ignore the Dim At setting and 

ONLY

 use the Stop At setting. .

Stop at: 

The user can select the “maximum” temperature that the 

growing area can get to before shutting down the lighting zones. This 
setting should normally be set at least 5’F up to 10 degrees F above the 
“Dim at” setting. If the temperature continues to rise in the growing 
area, the lights connected to each zone can be shut off to eliminate 
overheating of the growing area.

Sun R/S time: 

The DLM-4 Zone Controller can simulate Sunrise and 

Sunset. By slowly raising and lowering the lighting level (brightness) 
Sunrise and Sunset can be simulated. The user can select whether 
they want to use this feature or not by setting the Sun R/S time. 

The user can select up to 30 minutes in 5-minute increments for 
the Sunrise / Sunset feature. When the lights are turned on by the 
timeclock, the lights will gradually brighten to simulate morning, and 
when the lights are scheduled to turn off, they will dim to simulate 
the setting Sun. 

*NOTE: 

Using this function will 

NOT

 add additional Lights ON time to 

the light cycle.

SENSOR “ASSIGN”: 

Each of the temperature sensors can be assigned 

to separate control zones, or to multiple zones. Some users may want 
to assign each sensor to separate zones, others will want to use a 
single sensor to control multiple zones. Having the ability to assign 
the temperature sensors to each zone allows much greater flexibility. 
The user can select which temperature sensor will be assigned to each 
zone within this setting.

*NOTE: 

It is recommended that each zone has a separate temperature 

sensor for best / most accurate temperature measurements in large 
areas.

The Zone setup allows the user to select how to display the ballast 
watts of power as well as to “assign” a specific temperature sensor 
to each zone. Below shows another example of how the Zone page 
might look.

The user will set each individual zone up within the Zone pages. Once 
all of the Zones are set-up, the unit is ready for operation.

Zone 1

Wattage

Output Max

On at

Off at

Dim at

Stop at

Sun R/S time

Sensor

1000W

1000W

08:00am

08:00pm

88F

93F

OFF

Zone 1

Summary of Contents for DLM-4 ZONE

Page 1: ...DLM 4 ZONE Controller ...

Page 2: ...novations fixtures The controller is equipped with an easy to use menu system in six languages English Spanish German Dutch French and Mandarin The DLM 4 Zone Controller can be connected to up to 4 separate zones of DLI lighting fixtures Each zone can control up to 255 lights and 1 sensor so in total you can control 1020 lights and 4 sensors Once connected to the HIDs the controller will monitor a...

Page 3: ... cables and additional interconnect splitters can be purchased separately Ballast control is connected using RJ12 cables which are used to daisy chain the fixtures together Each of the ballasts comes with an RJ12 T splitter Each individual zone can have its own temperature sensor for more accurate control It is also possible to assign a specific temperature sensor to link with more than one lighti...

Page 4: ...ted to the controller Each zone can have separate dimming actions to take place and each zone can have it own separate temperature sensor that monitors the zone temperature All of the zones are controlled individually based on the 24 hour timeclock built into the DLM 4 Zone Controller Having 4 zones allows the user to create multiple lighting layouts and dimming sequences based on their individual...

Page 5: ...DESIRED PATTERN LOCATION FOR THE FIXTURES Determining the Zones Continued Once the lighting zones have been designed the ballast can be connected to the DLM 4 Zone Controller unit Each of the 4 available zones on the DLM 4 Zone Controller unit will have a separate cable connection to connect to the fixtures within each zone Simply connect a RJ12 cable to the desired zone connector on the bottom of...

Page 6: ...een set to operate using the External control Turn the selector switch on the side of each of the ballast to the correct position to allow the DLM 4 Zone Controller to control the ballast NOTE If the ballast selector switch is NOT positioned to allow External DLM 4 Zone Controller control the ballast will function manually without control DO NOT CONNECT THE POWER CABLES ON THE BALLAST UNTIL THE DL...

Page 7: ...em to be changed as well as to accept and enter the new setpoint into memory Familiarize yourself with the function of the 6 buttons on the front of the DLM 4 Zone Controller in order to able to access settings and to better understand how to use the DLM 4 Zone Controller to its greatest potential 7 1 Start Settings Once you have connected all of the Zone connections from the DLM 4 Zone Controller...

Page 8: ...guration page press Enter to access the Configuration page Once the Configuration page is displayed use the Up and Down buttons to navigate to the desired setting Press Enter to highlight the desired setting Use the Up and Down buttons to adjust the line item to your desired setting Pressing Enter will accept the change After Configuration is complete pressing the Back button will return to the Ma...

Page 9: ...an get to before shutting down the lighting zones This setting should normally be set at least 5 F up to 10 degrees F above the Dim at setting If the temperature continues to rise in the growing area the lights connected to each zone can be shut off to eliminate overheating of the growing area Sun R S time The DLM 4 Zone Controller can simulate Sunrise and Sunset By slowly raising and lowering the...

Page 10: ...ed to 7 6 Temperature Min Max Page Pressing the Find button on the DLM 4 Zone Controller will access some important functions The first page that will be displayed is the Temperature Minimum Maximum page Each of the temperature sensors installed will constantly measure the temperature and record the maximum high and minimum low temperatures These recorded temperatures can be used to confirm that t...

Page 11: ... current output status and at the time remaining before changing the ON OFF status 1 2 3 4 OVERRIDE FORCE PAGE Override Zone Force Zone 1 X 2 X 3 X 4 X 1 2 3 4 ON ON ON ON 04 09 07 04 09 07 04 09 07 04 09 07 Countdown 7 7 Manual OverRide Force page Occasionally the user may want to manually turn each lighting Zone On or Off manually Each of the 4 zones within the DLM 4 ZONE controller can be manua...

Page 12: ...g to factory presetting select the System Setup page in the Main menu and then select Factory Reset Pressing Enter will bring you the Factory Reset confirmation page you will be asked to confirm the Factory Reset press Enter or to press the Back button to cancel the reset and return to the previous page FACTORY RESET PAGE System Setup Factory Reset Firmware Update Firmware V_2 7 SN 001EC0FAE110 Pr...

Page 13: ...e needs to be updated follow the prompts on the computer to download a copy of the newest firmware onto a MicroSD card Insert the MicroSD card into the slot on the bottom of the DLM 4 Zone Controller unit Access the Firmware Update menu by going back to the System Setup menu and scrolling down to Firmware Update Press the Enter button to enter the firmware update menu Press Enter to scan the SD ca...

Page 14: ...tails including time and date of the event temperature recorded and a description of the event will be created by the DLM 4 Zone Controller and stored within memory to be viewed later The controller can record and store a total of 10 events The messages are accessed by pressing the Find button to display the stored messages and then pressing the Enter button in order to clear reset the message log...

Page 15: ...01 19 17 Zone 1 1000W Zone 2 Restrike Zone 3 Restrike Zone 4 Restrike 1000W70 7F 1000W Day F 14 31 F 14 31 F 14 31 7 14 Dimming and High temperature Shut Down The DLM 4 Zone Controller has the ability to monitor the temperature of 4 separate zones The user can select their desired dimming and high temp shut down Stop At settings within the zone settings Dim at setting If the temperature of any of ...

Page 16: ...om the date of purchase of the original product All returns need to be done in the original packaging in order to avoid damages of the product during transport Defective products need to be returned to factory or service shop for repaiir Non professionals Do not open the cabinet to prevent electric shock or damage to the equipment Pour tout retour le produit doit être replacé dans son emballage d ...

Page 17: ...receiving direct HID light which would increase the temperature reading The Zone does not seem to be controlled by the temperature sensor correctly The temperature display within one or more zones does not seem to be correct reading high Power was interrupted to the unit and now the lights will not turn on There is a 15 minute time delay after a power failure to prevent the lamps from hot starts T...

Page 18: ...n électrique Degree of ingress protection Indice de protection Certifications Certifications 12vdc 200ma 12 V CC 200 mA Backlit 9 lines x 16 characters 1000 meters each zone 1 degree F ETL FCC ETL FCC IP20 IP20 FOUR separate zones each with separate temperature sensors 1 Standard Additional sensors can be added up to 4 total Not limited can be placed anywhere inside growing area Use between 0 45 C...

Page 19: ...www dutchlightinginnovations com ...

Reviews: