7.13 Hot-start Prevention
If power is interrupted to the DLM-4, the unit will restart the lights after
a 15 minute time delay to allow the lamps to cool before re-starting.
Each successive zone re-start will be preceded by a 5 second delay in
order to reduce electrical startup surges / loads. During the 15-minute
delay, the DLM-4 will show the time remaining until the lights will be
re-started, (turned On).
*NOTE:
In order to minimize start-up load or high power “spikes”, after
a power outage each one of the 4-zones will be re-started sequentially.
After the first zone re-starts, a 5-second “cascading timer” delay will
begin for each of the remaining 3-zones to turn back on 1 at a time.
*NOTE:
While the time delay is counting down, the Zone status menu
will display the time remaining, before the lights are allowed to re-
strike.
01/19/17
Zone 1
1000W
Zone 2
Restrike
Zone 3
Restrike
Zone 4
Restrike
1000W
70.7F
1000W Day
---.--F
14.31
---.-F
14:31
---.-F
14:31
7.14 Dimming and
High-temperature Shut Down
The DLM-4 Zone Controller has the ability to monitor the temperature
of 4-separate zones. The user can select their desired dimming and
high-temp shut down (Stop At) settings within the zone settings.
Dim at setting:
If the temperature of any of the zones being monitored
rises too high, the lights connected (assigned) to that zone will be
dimmed to reduce the temperature inside the growing area.
Stop at setting:
If the temperature continues to rise, and the “Stop
At” temperature setting is reached, the lights within that zone will be
turned off.
*NOTE:
The zones will return to normal operation automatically once
the temperature is reduces by 2’C / 3.6’F below the dimming and the
Stop At setting. (The dimming or high-temp shutdown event will be
stored in memory within the error log menu.
*NOTE:
To return to the Zone status menu, press the Enter button.
Zone 1
Dimming start
04:41:25pm
03/08/2017
Temp: 70.8F
ENTER to Return