DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – SETTING THE DIFFERENTIAL
®
THE DIVERSITECH 675-TS32 THERMOSTAT ALLOWS YOU TO CON-
TROL UP TO 3 STAGES OF HEATING AND 2 STAGES OF COOLING,
DEPENDENT ON THE TYPE OF SYSTEM YOU HAVE CONFIGURED.
•
1
ST
STAGE DIFFERENTIAL:
Set temperature difference between temperature set
point and actual temperature reading before 1st stage heating or cooling is initiated.
•
2
ND
STAGE DIFFERENTIAL:
Set temperature difference between 1st stage initiation
and 2nd stage heating or cooling initiation.
•
3
RD
STAGE DIFFERENTIAL:
Set temperature difference between 2nd stage initiation
and 3rd stage heating or cooling initiation.
•
OB ENERGIZED:
Reverses the Heat Pump OB Valve contact to HEAT or COOL
(manufacturer dependent).
30
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION
ADVANCED SETTINGS – CONFIGURING YOUR EQUIPMENT
®
IMPORTANT: BY INADVERTENTLY MODIFYING COMPRESSOR AND
FURNACE SETTINGS, YOU MAY SERIOUSLY DEGRADE SYSTEM
PERFORMANCE.
®
CHOOSE SYSTEM HEATING AND/OR COOLING EQUIPMENT –
REMEMBER ALL YOU NEED TO DO IS TOUCH THE BUTTON WITH
YOUR FINGER.
•
Choose Heat Pump, 2 Stage Heat Pump, Air Conditioning, No Compressor – please
review the wiring table and diagram for wiring instructions.
•
Choose Furnace Off (No Furnace), Electric Furnace, Emergency Electrical Furnace
(additional electric furnace which will come on in emergency mode in conjunction
with electric furnace), Gas Furnace, Oil Furnace, and 2 Stage Gas Furnace; please
review the wiring table and diagram for wiring instructions.
•
CYCLE RATE:
Set Maximum compressor cycles per hour.
•
AUTO CHANGE:
Set the minimum difference between Auto Mode, Heat and Cool
temperature set points.