- 31 -
0DT872 01-12-2021
M
3 ~
140
0
U
V
W
9029
4327
Ø9
12
13
4. ELECTRICAL CONNECTIONS
The supplied cablings don't provide any intermediate connection, but they directly connect each device to the control board.
4.1. MOTOR CONNECTION
CONTROL BOARD SIDE
: insert the two cablings for motor and brake (code 9635), through the cable glands
4
and
3
(fig.11)
.
Insert the thermal protection cable through the cable gland
7
. Fit the connectors on the control board as shown at par.
5.1
.
MOTOR SIDE: open the junction box, disconnect and remove the cablings 4327 and 9029
(fig. 12)
. Drill a hole Ø9 on the
box
(fig. 13)
and insert the grommet, present on the cabling 9634. Insert the cablings 9634 and 9635 and connect to the
terminals as shown at
par.5.1
. Connect the cable with ring nut to the encoder
(fig.14)
.
1
2
3
4
5
6
7
8
11
Blue
Black
Grey
White
Rod
Yellow/green
Black
Brown
Disconnect
14
Motor (9635)
Brake (9635)
Thermal protection (9634)
EN