- 37 -
0DT872 01-12-2021
FUSES
ID
Value
Size
Circuit
F1 - F2
12A - 500V
10.3 x 38
Single phase line
COMMAND
NOTES
Opening position
at 200 mm from the crosspiece
Partial opening position
From 200 mm, from floor to
opening position
Closing position
on floor
POSITION ADJUSTMENT
TROUBLESHOOTING
Display message
Problem
Check
Current limit exceeded
Requested motor torque
exceeds available torque.
• Reduce opening speed.
• Check power supply.
• Check power supply wiring.
Encoder battery
Absolute encoder battery flat or
position read error
• Switch off the control panel, wait 3 minutes and
reconnect the power supply.
If the problem is not resolved, try again.
• If the encoder battery message remains displayed,
replace the encoder.
Insert brake resistance
Voltage on BUS exceeds
threshold
• Switch off the control panel, wait 3 minutes and
reconnect the power supply.
• If the error reoccurs, check that the voltage on the
BUS is lower than 360 V.
Max. BUS voltage
BUS voltage exceeds threshold
• Switch off the control panel, wait 3 minutes and
reconnect the power supply.
• Check the control panel power supply voltage.
52E
P5
P3
P4
P1
P2
41 40 20 9 8 4 3 2 1 1 0 LAMP
1 11 12 13
ON
OFF 1 2 3 4 5 6 7 8
DL
2 3 4 5 6 7
DL
M7
M4A
M5
M6
M3
BACK
M4
1 IN NC C NO
M2
J4
15
S3 S4
S5
S2
SAFETY
OPEN
F2
F1
230 V
50/60 Hz
GND
L
N
+F -F U V W
ON
EN