distyNotruf

Operating Instructions

Summary of Contents for distyNotruf pro

Page 1: ...distyNotruf Operating Instructions ...

Page 2: ...ng Call default not activated 14 Volume level 15 DECT Activity default enabled 15 Shock sensor Motion alarm default disabled 15 Man down 16 Motion detection 16 Man Down Horizontal 17 Man Down Accelerometer 17 Announcement tone off bell ring tone default disabled 18 Performance characteristics Hospital default disabled 19 Service call 20 Out of Range default not activated 20 Battery alarm default a...

Page 3: ... possible Do not leave the battery for a long time in a discharged state Keep the battery away from heat sources such as Heaters and open flames such as Candles Danger of explosion Do not use charging devices that are damaged in any way Do not disassemble or deform the battery Your hands and fingers may be injured or battery fluid may get into your eyes or on your skin If this happens rinse the ar...

Page 4: ...r telephone extension by simply pressing the push button With the help of an integrated acceleration sensor the tag is also able to initiate an alarm call automatically This Operating Manual is meant for the administrator of the facility who is well informed about the DECT technology and has the duty of setting and managing this special terminal device Also this manual describes the variant distyN...

Page 5: ...distyNotruf pro Operating instructions The IPEI serial number e g 014231011124 is printed on the label Application Page 3 of 33 Bottom view incl both spring bars Components of a DECT system ...

Page 6: ... side of the charging plug Press the middle tab of the clip through the clamp and push it under the mounted spring bar Insert the second spring pin into the opposite end of the clip Move the clip to the approximate end position as shown above Insert the one side of the spring bar into the hole provided for this purpose Press the other side of the spring pin towards the clip locking the clip into t...

Page 7: ...ation code AC is 0000 The distyNotruf is prepared through the following procedure The process functions only if the device is not subscribed See chapter on Factory setting The device is plugged into the CS Press the key within the next 5 seconds and wait 10 sec for the green LED to light up Now let go off the key The function has now been activated The green LED begins to flash This indicates that...

Page 8: ...em is activated for subscription the administrator has disclosed the SARI used e g 3111111111115 and the new terminal device set up in the system The SARI is entered in the device through the programming station PS see chapter on Configuration of parameters changing functionality Function 14 Subscription is now performed as described above Configuration Some settings were made in the device during...

Page 9: ...s is the last step required by the system administrator to delete the subscription data of the distyNotruf from the system and thus unsubscribe the device Subscription data are deleted also by resetting to the default status Factory setting After a maximum of 3 minutes the distyNotruf switches to the sleeping mode no LED lights up DECT activity is stopped A special feature is the Factory setting c...

Page 10: ...ard Press the alarm key latest after 5 seconds and hold for 10 seconds Green LED illuminates Let go of alarm key before LED switches off 2 seconds time A 450 Hz tone is heard and red LED illuminates Remove distyNotruf from charging cable distyNotruf switches to power down every function is switched off programmed alarm numbers are not deleted NOTE The correct function of the alarm numbers has to b...

Page 11: ... sensor Not active Hospital Not active Authentication code AC up to eight digits 0000 PIN 0000 Hotline Not active Off hook mode for incoming call Key Out of range during connection Active Out of range Standby Not Active DTMF Protocol Not active Note Alternatively the factory setting can be established through the Programmer App see next chapter Function 5 6 The device can be disconnected from the ...

Page 12: ...hould be connected with the cable as indicated above It is important to choose the right direction of the jack Otherwise the data transmission with the PC will not work Note If necessary the installation of a driver Virtual COM Port may be required see installation advice of the programmer app The distyNotruf is not connected during installation The properties of the interface are 19200 Baud 8N1 T...

Page 13: ...r line shows the actual status After the PS has recognized the distyNotruf the communication begins the LEDs of the tag will both be switched on All relevant data are read from the device The status line will light up in green color The tool is ready for use Now you can choose the function or value you want to change As an Example the alarm number go to sheet Configuration 1 write the appropriate ...

Page 14: ...he session by pressing the upper left button again The tag will re start and is ready for use The PC or USB hub can be used as charging station for the tag The distyNotruf is plugged in and out to the charging cable as usual NOTE Hints are shown while the cursor hoovers over the objects on the sheet see the green colored text above If read and its nearby write button are gray then the value s are ...

Page 15: ...ogrammed number the red LED flashes That is a speech connection This can be terminated just by pressing the button again The emergency call is set through function 10 If a distyNotruf is called which has no emergency number set then it stores the callers identity CLIP2 as emergency number To outperform this function the device must not be in charging conditions The alarm number and other parameter...

Page 16: ...successful emergency call and attempts to select it again or one of the additional programmed numbers This ensures that an alarm is will reach the human helper and not shipped on a mailbox or an answering machine An exception are internal calls In this case confirmation is not necessary because usual DECT Handsets can not send the appropriate acknowledgment Call acceptance off hook mode standard p...

Page 17: ...e is switched off during charging see Function 24 2 Note The alarm functionality of the alarm button is enabled 5 sec after connecting the device with the charging cable The activity of the acceleration sensor see next chapter is stopped while charging Shock sensor Motion alarm default disabled Performance characteristics serve the purpose of recognizing an accident on the part of the bearer e g f...

Page 18: ... is performed through Function 21 Timeout time can be set in this case between 20 and 254 seconds The man down variation will then be active in the basic setting It will be set to motion detection by setting the checkbox If an event is triggered a speech connection established This will be shown through a brief flashing of the red LED The feature is switched off in the CS Examples of setting the f...

Page 19: ...econds Man Down Accelerometer If feature is active the distyNotruf can detect a typical acceleration profile of a falling person On this event an alarm call is initiated The combination of the man down functions are ored The function whose conditions match will start the call first Before this a so called pre alarm phase with a duration of for example ten seconds is started This is indicated visua...

Page 20: ...r a successful acknowledged alarm and can be switched off at the device by means of push button sequence or remotely see chapter Indication tones and Setting via DTMF Announcement tone off bell ring tone default disabled When you get a call there is an audible indication in form of a short beep The locator options setting can be changed so that this sound is not heard e g in a baby sitter applicat...

Page 21: ... alarm call Patient receives visual and acoustic feedback Nurse is informed through her his handset and can get back to patient After 10 minutes without connection the device switches off completely again and is ready for new alarm The following parameters are used as setting Emergency number Function 10 Locator options Register Configuration 2 Function 24 4 This features increases the standby tim...

Page 22: ...ed The distyNotruf starts a call when the battery capacity has almost run out So that another person as the wearer of the distyNotruf is informed that the device should be recharged soon The signaling corresponds to the description out of range See also Configuration 2 tab Function 24 5 Operation with alarm server default not activated The distyNotruf is able to work with so called alarm servers o...

Page 23: ...ted the following table shows the different types 1 Emergency button 2 briefly pressed alarm double pressure within 2 s 2 Press and hold the emergency call button test 1 s pressed 3 Resting alarm 4 Motion alarm 5 6 not assigned 7 low battery 8 connected with CS 9 removed from CS 0 Localization info distyNotruf was called for position inquiry The following tones are controlled by the following comm...

Page 24: ...arameter can be modified Authentication Code AC 9 pin 5 ac ac 0 9 4 8 digits Volume of loudspeaker 9 pin 1 Volume value Volume value 1 5 Volume of ringing tone 9 pin 4 Volume value Volume value 1 2 Emergency call number 9 pin 2 Calling number 6 Calling number max 20 digits Busy call number 9 pin 6 Index 7 phone number phone number max 20 digits Indication tone 9 pin 7 Ton type 8 Off hook mode 9 pi...

Page 25: ...n be activated from the remote subscriber at the distyNotruf This is used e g to support the search for the wearer of the tag after a man down alarm location tone Or in the case of a general danger situation to inform the wearer quickly Amok alarm e g to leave the building in case of a fire alarm Via a secret key combination the sound can also be switched off locally at the distyNotruf The followi...

Page 26: ...th a tone generator a telephone mobile phone or a PC program In the case of a telephone a connection is made to any subscriber Then place the distyNotruf near the earpiece or speaker of the phone push the button on the distyNotruf and now select the above described combinations of numbers on the push button at the telephone The successful programming is indicated by a positive acknowledgment tone ...

Page 27: ...ce in every 30 seconds and beep tone11 6 Subscribed registered Green LED flashes once in every 10 seconds 7 Subscribed out of range searching for base station Red LED flashes every second 8 DECT connection Green LED is switched on 9 Alarm Red LED flashes twice a second 10 Range Limit Red LED flashes fast Warning tone 11 Status on delivery Default Pressing the button Red and green LEDs on 12 Progra...

Page 28: ...structions Package list The following items will be found together with the distyNotruf in the box distyNotruf two spring bars mounted Bracelet mounted Belt clip Neckband Users manual Card box Power Supply and Cable Page 26 of 33 ...

Page 29: ...harging Programming method Power supply and cable Motion sensor Loudspeaker for acoustic signaling or speech output Button for emergency call and operation LEDs for operative display 2 colors Microphone Lithium ion battery Capacity 450 mAh 3 7 V Charging time about 4 hrs for a complete charging cycle Operating temperature 10 C bis 40 C13 Storage temp 10 C bis 60 C 12 In environment temperature of ...

Page 30: ...distyNotruf pro Operating instructions Page 28 of 33 ...

Page 31: ...distyNotruf pro Operating instructions Page 29 of 33 ...

Page 32: ...distyNotruf pro Operating instructions If the Logfile checkbox is selected a blue window will be opened whose contents will also be written to a file example logfile_16 09 20_15 06 09 txt Page 30 of 33 ...

Page 33: ...e devices Load Configuration Set a specific configuration Save configuration as save the settings of a connected device to a file Can be read in again using the previous function Language selection for display in the Programmer app in various languages Display of variant and version Page 31 of 33 ...

Page 34: ...undamental requirements and other relevant regulations stated in Directive 1999 5 EU Radio and Telecommunication Terminal Equipment R TTE Conformity is declared by the CE mark The full declaration of conformity can be viewed on our website http www disty de Table of pre programmed phone numbers Phone number Note Name 1 2 3 4 5 Page 32 of 33 ...

Page 35: ...to Friday 9 am 5 pm phone 49 0 4 31 3 64 58 22 http www disty eu Operating instructions distyNotruf All rights to changes reserved Copy also some extracts needs a written permission disty communications gmbh Holzkoppelweg 14 D 24118 Kiel Version 1 0 Germany Edition 10 2016 Page 33 of 33 ...