Troubleshooting cases
USER_MAN_ENG_MCWN
TROUBLESHOOTING CASES
TARE
The scale does
not tare
•
The weight is unstable (
unStAb
)
•
The gross weight is negative (
loW
)
•
The weight is insufficient
•
The weight exceeds the maximum capacity
•
The tare function has been disabled
•
With manual tare, the value exceeds the maximum capacity
WEIGHING
The scale does
not switch on
•
Check the correct insertion of the battery holder.
•
Replace the battery and try again. If the instrument continues to malfunc-
tion, contact the dealer.
The scale switches
off suddenly
•
Automatic switch-off enabled
•
Low battery
•
Power supply line failure
The scale is
not reactive
•
One of the available energy saving modes has been enabled
•
An unsuitable weighing filter has been selected
The scale screen
switches off and
displays a dot
•
Stand-by mode is enabled: press a key to re-enable weighing.
•
Energy saving mode is enabled: contact the dealer for further details.
The scale displays
a permanent “
Zero
”
message
•
The scale is unable to automatically reset the weight because it exceeds
the maximum resettable weight at switch-on.
•
Release the hook and try again. If the scale continues to have the same
problem even when the hook is unloaded, contact the dealer.
The weight is
unstable
•
Check whether the weighing filter is enabled.
•
If the system is subjected to vibrations from machinery or moving vehi-
cles, move the scale onto another surface and try again.