MCW-MCWR2 PROFESSIONAL MCW_03_12.10_EN_U
42
3.2.6 Electronic crane scale battery: instructions and recharge
As mentioned earlier, the power supply in MCW/MCWK electronic crane scale is provided through a rechargeable 6V – 4,5
Ah, to be included in the box on the back of the equipment (see section “MAIN COMPONENTS”).
In order to prevent problems with the battery, it is recommended to remove the battery from the load cell, if the electronic
crane scale is not used for a long time so as not to cause damage to both the battery and the crane scale itself.
The electronic crane scale displays "LoW.BAt" when the batteries are about to complete their life cycle. In this case, it is
necessary to connect the crane scale to external power (12Vdc) to fully recharge the battery.
In order to recharge the battery, you must:
- Remove the rubber cap from the connector on the back of the crane scale;
- Insert the jack of the feeder (12V) in the connector on the back of the instrument;
- Insert the power supply (12V) in the power outlet at 230VAC;
Later, on the indicator front panel lights the LED power-on LED lights.
Never throw the battery into the fire, will bring them closer to sources of heat can cause explosions and injuries.
CAREFUL!!