OPERATOR
’S MANUAL
with Maintenance Information
Function Tests
23
1 Select a test area that is firm, level and
free of obstruction.
At the Ground Controls
2 Pull out the platform red Emergency Stop
button to the on position.
3 Turn the red Emergency Stop button
clockwise to the on position.
4 Turn the key switch to ground control.
5 Observe the display on the ground
controls.
⊙
Result: The display readout will come on
and display SYSTEM READY.
6 Start the engine. See Operating
Instructions section.
Test Emergency Stop
7 Push in the ground red Emergency Stop
button to the off position.
⊙
Result: The engine should turn off and no
functions should operate.
8 Turn the red Emergency Stop button
clockwise to the on position and restart the
engine.
Test Up/Down Functions and
Function Enable
A buzzer with different sound frequency is
controlled in central system. The descent
alarm sounds at 60 beeps per minute. The
descent
delay alarm sounds at 180 beeps per
minute The alarm that goes off when the
machine is not level sounds at 180 beeps per
minute. An optional automotive-style horn is
also available.
9 Do not press the lift function enable button.
Press and hold the platform up/down
button.
⊙
Result: No function should operate.
10 Press and hold the lift function enable
button. Press and hold the platform up
button.
⊙
Result: The platform should rise.
11 Press and hold the lift function enable
button. Press and hold the platform down
button.
⊙
Result: The platform should lower the
descent alarm should sound while the
platform is lowering. The platform stop at
the height is approximately 3.5 m from the
ground.
The descent delay alarm will
sound.
Note: Be sure the area below the platform is
clear of personnel and obstructions before
continuing.
12 Press and hold the lift function enable
button. Press and hold the platform down
button.
⊙
Result: The platform should lower to end.
The descent delay alarm should sound
while the platform is lowering.
Test the Auxiliary Lowering
13 Activate the up function and raise the
platform approximately 60 cm.
14 Press the engine start/ flameout button to
engine off.
15 Press and hold the lift function enable
button. Press and hold the platform down
button.
⊙
Result: The platform should lower.
16 Turn the key switch to platform control and
restart the engine.
Test the Emergency Lowering
17 Activate the up function and raise the
platform approximately 60 cm.
18 Press the engine start/ flameout button to
engine off.
19 Press and hold the emergency lowering
down enable button. Press and hold the
Summary of Contents for JCPT2223RT
Page 3: ......
Page 17: ...OPERATOR S MANUAL with Maintenance Information Decals 12 ...