EN-18 452162.66.04 · FD 9309
www.dimplex.de
English
LAW 9IMR - LAW 14ITR
13 Device information
1
Type and order code
LAW 9IMR
LAW 14ITR
2
Design
Heat source
Air
Air
2.1
Model
Split reversible
Split reversible
2.2
Controller
WPM Econ5Plus integrated
WPM Econ5Plus integrated
2.3
Thermal energy metering
Yes
Yes
2.4
Installation location
Indoors / outdoors
Indoors / outdoors
2.5
Performance level
Variable
Variable
3
Operating limits
3.1
Heating water flow / return
°C
up to 55 / from 18
up to 55 / from 18
3.2
Cooling water flow
°C
7 to 25
7 to 25
3.3
Air (heating)
°C
-20 to +30
-20 to +30
3.4
Air (cooling)
°C
+10 to +43
+10 to +43
4
Flow / sound
4.1
Heating water flow / internal pressure differential
in accordance with EN 14511
m³/h / Pa
1,6 / 20000
2,4 / 30400
free compression
Pa
38800
29600
Minimum heating water flow
m³/h
0,75 / 8500
0,9 / 10000
free compression
Pa
68500
77300
4.2
Noise-power level in accordance
with EN 12102 outdoors
1
dB(A)
63
67
4.3
Sound pressure level in 10 m distance outdoors
2
1
dB(A)
32
36
4.4
Noise-power level in accordance
with EN 12102 indoors
dB(A)
42
42
4.5
Sound pressure level in 1 m distance indoors
dB(A)
35
35
4.6
Air flow
m³/h / Pa
3600
3600
5
Dimensions, weight and filling quantities
5.1
Device dimensions
3
internal
H x W x D mm
external
H x W x D mm
1920 x 740 x 950
834 x 950 x 330
1920 x 740 x 950
1380 x 950 x 330
5.2
Weight of the transportable unit(s)
incl. packaging internal / external
kg
215 / 69
222 / 116
5.3
Device connections for heating
inches
G 1 1/4"
G 1 1/4"
5.4
Refrigerant; total filling weight
type/kg
R410A / 1.9
R410A / 2.98
5.5
Lubricant; total filling quantity
type/litres
Polyvinyl ether (PVE) / 0.9
Polyvinyl ether (PVE) / 1.3
5.6
Volume of heating water in the outdoor component
Litres
0
0
5.7
Buffer tank
Nominal volume
in litres
100
100
Permissible operating temperature
°C
85
85
Max. operating overpressure
bar
3,0
3,0
Electrical pipe heater
kW
2, 4 or 6
4
2, 4 or 6
4
Immersion heater (optional)
kW
up to 6
up to 6
5.8
Domestic hot water cylinder
Usable capacity
in litres
277
277
Heat exchanger area
m²
3,15
3,15
Permissible operating temperature
°C
95
95
Max. operating pressure
bar
10,0
10,0
Immersion heater
kW
1,5
1,5
5.9
Start-to-leak pressure, safety valve
bar
2,5
2,5
Summary of Contents for LAW 14ITR
Page 2: ......
Page 22: ...DE 20 452162 66 04 FD 9309 www dimplex de Deutsch LAW 9IMR LAW 14ITR ...
Page 42: ...EN 20 452162 66 04 FD 9309 www dimplex de English LAW 9IMR LAW 14ITR ...
Page 62: ...FR 20 452162 66 04 FD 9309 www dimplex de Français LAW 9IMR LAW 14ITR ...
Page 83: ...www dimplex de 452162 66 04 FD 9309 A XXIII Anhang Appendix Annexes LAW 9IMR LAW 14ITR ...