Fig. 5.4
Installation on wall brackets is not advisable, as this frequently
leads to noise problems.
If this type of installation is used, observe the following instruc-
tions:
Fit rubber buffers
Take the weight of the outdoor unit into account
Ensure that the wall bracket is no higher than 1 m above the
ground
Ensure that minimum clearances are adhered to
Fig. 5.5
5.2.1 Wall opening for split lines and
electric wires
Please proceed as follows when laying split lines and elec-
tric wires:
Drill a 70 mm opening for the pipework using a core drill
The opening for the pipework should be slightly inclined to-
wards the outdoor unit, so that no rainwater can penetrate
the building.
5.2.2 Wall opening for condensate drain
1,5 m
1,5 m
2 m
0,3
m
0,3
m
1,5 m
1,5 m
2 m
0,3
m
0,3
m
:DOO
aPP
,QGRRUXQLW
2XWGRRUXQLW
aPP
:DOO
,QGRRUXQLW
2XWGRRUXQLW