DL9120 / DL9130
Operating Instructions
- 37 -
6.4 Line Impedance
Supply Voltage
195V
– 253V, 45Hz – 65Hz
328V - 440V, 45Hz
– 65Hz
Nominal Test Current
3A
Display Range
0.01
- 2000
Measuring Range
0.1
- 1999
Resolution
0.01
maximum
Accuracy
±5% ±5 digits
PFC Range
0kA
– 26kA
6.5 RCD
Supply Voltage
195V
– 253V, 45Hz – 65Hz
Nominal Test Currents
10mA, 30mA, 100mA, 300mA,
500mA and Variable Mode
Test Current Accuracy
-0% +10% at I
n and 5I
n
-10% +0% at ½ I
n
Trip Time Ranges
0ms
– 2000ms, ½ I
n
0ms
– 300ms, I
n General
0ms
– 500ms, I
n Selective
0ms
– 40ms, 5I
n
Trip Time Accuracy
±5% ±2 digits
Ramp Current Range
½ I
n to 1.1 I
n
Trip Current Measurement
Accuracy
10%
6.6 RDC-DD (DL9130EV only)
Supply Voltage
195V
– 253V, 45Hz – 65Hz
Nominal Test Currents
6mA
Test Current Accuracy
-0% +10%
Trip Time Ranges
0ms
– 10000ms
Trip Time Accuracy
±5% ±2 digits
Ramp Current Range
½ I
n to 1.1 I
n
Trip Current Measurement
Accuracy
10%
6.7 Voltage/Frequency Measurement
Display Range
0V
– 480V
Voltage Measuring Range
0V
– 480V
Resolution
1V
Accuracy
±5% ±2 digits
Frequency Range
45Hz
– 65Hz
Frequency Accuracy
±1Hz