1. 

The 

Loco Info Area

 is where the current locomotive information for the 

throttle knob is shown.   At left is a direction arrow icon with the current 

direction indication. Showing forward as “F” inside an arrow, or reverse, 

shown with an “R” inside the arrow. If a locomotive address is currently 

selected this arrow icon will be 

green

.  If no loco is selected the icon will 

be 

gray

.   The currently active address is shown in the large numbers in the 

center. If a loco is selected the numbers will be solid 

black

, if no loco is 

selected the numbers will be 

gray

. The 

LCD 

will show additional informa-

tion during locomotive selection, see section 

4.0

 for more information on 

selecting locomotives.

2.  The 

Status Bar 

is active for Home screen and will show the status of your 

throttle.  There are multiple indicators that appear in the 

Status Bar

. An 

“Ln” indicator shows when LocoNet is connected OK. The “Trk” indicator 

is green when system track power is turned on.  In IR or Duplex mode 

connection information is shown if the throttle is unplugged and the IR or 

Duplex modes are enabled with LocoNet support found.  The battery sym-

bol shows approximate battery power when the throttle is unplugged

3.  The 

Function Info Bar

 is where the state of a group of ten functions are 

displayed

.  

Active/ON function numbers are blue and inactive/OFF func-

tions are grayed out. For more info on controlling and managing functions 

see section 

5.0

.

4.  The 

Lower soft key line

 shows alternate available numeric soft key 

actions when not in home screen state

5.  The 

Upper soft key line

 shows alternate available numeric soft key 

actions when not in home screen state

6.  Scrolling Help

 text line. Shows status and prompts user actions.

2.1.2 Screen IDLE Power saver

To save power and be ecologically responsive, the UT6 will enter a dark dis-

play screen-IDLE after a user configurable no-activity timeout  When in a 

power saving IDLE mode the heartbeat LED will flash green about every 3 

seconds. To exit IDLE mode press the 

 or   key to restore the color LCD 

home display.  

A short press of the   key is a consistent way to return to the 

HOME screen from any menu.  

Note: holding the the   key for more than 

about 1 second will perform Emergency Stop. See section 8.0.

Summary of Contents for UT6 Series

Page 1: ...helpdesk digitrax com www digitrax com Digitrax Manuals Instructions are updated periodically Please visit www digitrax com for the latest version of all manuals for available firmware updates Digitra...

Page 2: ...tep settings 12 4 8 Multiple Unit MU or Consist operations 12 4 9 Adding a Locomotive to an MU 13 4 10 Removing a Locomotive from an MU 14 4 11 MU of mismatched locomotives 14 4 12 Controlling functio...

Page 3: ...and connected to a compatible Digitrax USB device The UT6 functions and screens may change with updates from the Digitrax Web site so be sure to check the UT6 product pages to get the latest informati...

Page 4: ...Key Switch Key Color LCD screen Throttle knob Forward Brake Reverse switch Figure 1 UT6 family controls and LCD screen view Heartbeat LED 0002 F sp 50 Fn0 0 1 2 3 4 5 6 7 8 9 DigiT30 12 Trk Press loco...

Page 5: ...en arrow symbol showing direction and a current speed indication above this The scrolling HELP prompt line at the bottom of the display pro vides useful operating hints and information in context as y...

Page 6: ...lor LCD screen The screen provides a variety of information and input prompts to assist in running locomotives and system setup This section outlines the Home Operations Screen other menu displays wil...

Page 7: ...on is shown if the throttle is unplugged and the IR or Duplex modes are enabled with LocoNet support found The battery sym bol shows approximate battery power when the throttle is unplugged 3 The Func...

Page 8: ...ls to get through the white LED will flash and if layout Duplex support fails the NetName will change to red text 3 1 Recharging a Digitrax BP600MH Battery pack 1 Remove the 3 AA batteries from the UT...

Page 9: ...number will provide you addition al information about the loco address num ber you are selecting If it says free the locomotive is available for selection If it says busy the locomotive is in use on...

Page 10: ...key pressed the key is now a soft key showing address Recall choice Press this key to bring up the non volatile list of the last 6 unique addresses used on this UT6 When in Recall Session Loco List s...

Page 11: ...ired by another throttle Only one address at a time can be marked as a dispatched address in the system To dispatch a locomotive address using the UT6 1 Press the key to enter address selection enter...

Page 12: ...lection and speed step setting change Once this change is made the Digitrax command station will send DCC commands to the edited decoder in the speed step setting you entered 4 8 Multiple Unit MU or C...

Page 13: ...o use to control the MU This will be the TOP address To do this press enter the address numbers press again 3 Press again to re enter loco selection mode and the large TOP address numbers in the Loco...

Page 14: ...MU have performance characteristics that are closely matched you can run all the MU ed locomotives in e g 128 step mode If the units are completely mismatched for example if you are running two diffe...

Page 15: ...operate functions F0 F9 on your locomotive Select the loco you want to control Press the key until you see Fn0 at the left of the Function line This group means numeric 0 9 keys now control functions...

Page 16: ...There is no F29 DCC function 5 4 Troubleshooting Function Operation If the function you want to operate does not respond check the following 1 Is Track Status Power on If not press the Power Back Key...

Page 17: ...switch address selection and not function control 7 0 Expanded Menu Features To reduce display clutter the UT6 places expanded menu choices in a menu system accessed by the or MENU key Pressing the ke...

Page 18: ...ets the time at the lower ID16 level before the display turns OFF for maximum power save and battery life Higher numbers increase LCD brightness and delays Option ID8 Enc LCD wake and ID9 FnKey LCD wa...

Page 19: ...on a powered layout immediately Press the key then the key to turn OFF track power to the whole layout This option will stop everything on the layout without knowing what locomo tive is on which thro...

Page 20: ...Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help OEM RF28 Manufacturer Respons...

Page 21: ...nty before continuing onto this section Digitrax gives a one year no worries warranty against manufacturing defects and accidental customer damage on all Digitrax products That s it Simple straightfor...

Page 22: ...2020 Digitrax Inc www digitrax com 22 22 This page left intentionally blank...

Page 23: ...2020 Digitrax Inc www digitrax com 23 23 This page left intentionally blank...

Page 24: ...in a particular locomotive Digitrax CV Calculators www digitrax com support cv Calculate a CV value to program your locomotive Digitrax Tool Box App www digitrax com toolbox Download our Mobile App f...

Reviews: