7. Appendix
Digital Projection
TITAN sx+600/700.
User Manuall
Operation Messages
Operation messages are constructed using the following format:
Header
Type
Size
CRC
Oper’n
type
Operation
Reserved
2 bytes
1 byte
2 bytes
2 bytes
1 byte
2 bytes
2 bytes
Data
BE
EF
03
19
00
58
58
00
00
00
00
00
Byte #
1
2
3
4
5
6
7
8
9
10
11
12
Operation Target
Operation Value
Reserved
4 bytes
4 bytes
4 bytes
Data
00
00
00
00
00
00
00
00
00
00
00
00
Byte #
13
14
15
16
17
18
19
20
21
22
23
24
Reserved
Reserved
4 bytes
4 bytes
Data
00
00
00
00
00
00
00
00
Byte #
25
26
27
28
29
30
31
32
Header is always
EFBE
h (byte 1 =
BE
h and byte 2 =
EF
h)
Type is always
03
h for Operation Messages
Size is always
0019
h (byte 4 =
19
h and byte 5 =
00
h) i.e. 25 bytes after CRC
CRC can be set to
5858
h if you want the CRC to be ignored. However, the CRC
should ideally be calculated, as described in the
Titan Projector Series External
Control Protocol
.
Operation type is one of the following:
Set
01
h
Get
02
h
Increment
03
h
Decrement
04
h
Execute
05
h
Set
writes a value to the projector.
Get
reads a value from the projector.
Increment
and
decrement
increase or decrease a value by one unit.
Execute
executes the current operation (specific commands only).
Spaces in the example messages are for visual clarity and should not be sent as
part of the message.
Notes
The following pages contain
examples of some basic
Operation commands.
For full details of all the For
full details of all the Operation
commands and Enhanced
commands, contact Digital
Projection and ask for a copy
of the
Titan Projector Series
External Control Protocol.