Chapter 2. HP–UX
EK–SM410–UP. A01
2–9
Next, verify the storagesets you have configured:
swxrc> show storage full
The controller responds with a display similar to that shown below:
NAME
STORAGESET
USES
USED BY
S28
STRIPESET
DISK130
D100
DISK230
DISK330
DISK430
DISK530
DISK630
SWITCHES:
CHUNKSIZE = 256 BLOCKS
STATE:
NORMAL
DISK130 (MEMBER 0) IS NORMAL
DISK230 (MEMBER 1) IS NORMAL
DISK330 (MEMBER 2) IS NORMAL
DISK430 (MEMBER 3) IS NORMAL
DISK530 (MEMBER 4) IS NORMAL
DISK630 (MEMBER 5) IS NORMAL
SIZE: 50268168 BLOCKS
M1
MIRRORSET
DISK400
D200
DISK500
SWITCHES:
POLICY (FOR REPLACEMENT) = BEST_PERFORMANCE
COPY (PRIORITY) = NORMAL
READ_SOURCE = LEAST_BUSY
MEMBERSHIP = 2, 2 MEMBERS PRESENT
STATE:
NORMAL
DISK400 (MEMBER 0) IS NORMAL
DISK500 (MEMBER 1) IS NORMAL
SIZE: 4109470 BLOCKS
R5
RAIDSET
DISK210
D300
DISK310
DISK410
SWITCHES:
POLICY (FOR REPLACEMENT) = BEST_PERFORMANCE
RECONSTRUCT (PRIORITY) = NORMAL
CHUNKSIZE = 256 BLOCKS
STATE:
NORMAL
DISK210 (MEMBER 0) IS NORMAL
DISK310 (MEMBER 1) IS NORMAL
DISK410 (MEMBER 2) IS NORMAL
SIZE: 25134084 BLOCKS
SPARESET
SPARESET
FAILEDSET
FAILEDSET
SWITCHES:
AUTOSPARE