![Digital Equipment StorageWorks RAID Array 410 Installation Manual Download Page 27](http://html1.mh-extra.com/html/digital-equipment/storageworks-raid-array-410/storageworks-raid-array-410_installation-manual_2498885027.webp)
Chapter 1. Digital Unix
EK–SM410–UP. A01
1–15
Figure 1
−−
4 Attaching the Connecting Cables
Figure 1–5 Connecting the Cache Module to the Cache Battery
3. Connect the cache module to the external cache battery (ECB) SBB as shown in
Figure 1
−
5.
4. Insert the new program card into the new controller. The program card eject button
extends when the card is fully inserted.
5. Snap the ESD shield into place over the program card.
6. Power ON the entire subsystem.
7. If the controller initializes correctly, its green reset LED begins to flash at 1 time per
second. If an error occurs during initialization, the OCP displays a code. If necessary,
refer to Chapter 1, Troubleshooting in the Servicing your StorageWorks Subsystem,
HSZ50 Array Controller, HSOF Version 5.0 to analyze the code.