![Digital Equipment StorageWorks RAID Array 410 Installation Manual Download Page 122](http://html1.mh-extra.com/html/digital-equipment/storageworks-raid-array-410/storageworks-raid-array-410_installation-manual_2498885122.webp)
Chapter 6. NetWare–PCI
EK–SM410–UP. A01
6–5
In the following steps, you should record your configuration for future reference.
Next, record the Logical Units you have configured:
swxrc> show units full
The controller responds with a display similar to that shown below:
LUN
Uses
D100
S28
Switches:
RUN
NOWRITE_PROTECT
READ_CACHE
WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = THIS_CONTROLLER
Size: 20547350 blocks
D200
M1
Switches:
RUN
NOWRITE_PROTECT
READ_CACHE
WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = THIS_CONTROLLER
Size: 4109470 blocks
D300
R5
Switches:
RUN
NOWRITE_PROTECT
READ_CACHE
WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = THIS_CONTROLLER
Size: 8216924 blocks
Record, and mark when enabled, the information in the following table. The top line
shows how to record entries for D300 of the sample.