Troubleshooting
3.3 Troubleshooting Chart
Use this section to find a symptom, probable cause, corrective action, and
references to the FRU procedure only after you have gone through all the
checks and procedures in the previous sections.
Table 3–3
Storage Enclosure Troubleshooting Chart
Symptom(s)
Probable Cause(s)
Corrective Action(s)
No OCP indicators
are lit.
1.
Storage
enclosure is
not plugged in or
not turned on.
1.
Plug in the ac power
cord or turn on the AC
power.
2.
Drive dc power
switch is off.
2.
Turn on the drive dc
power switch.
3.
OCP is not
plugged in or
seated firmly.
3.
Press the OCP firmly in
place.
4.
Bad OCP.
4.
Configure and replace a
new OCP.
5.
Bad transition
module.
5.
Configure and replace a
new transition module.
6.
Bad power
supply.
6.
Replace power supply.
7.
Bad ac power
cord.
7.
Replace ac power cord.
8.
Ise not seen.
8.
Reseat ISE into
backplane.
1
1
This step only applies to SF3x storage enclosures.
Summary of Contents for EK-SFXXS-SG-003
Page 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Page 10: ......
Page 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Page 24: ......
Page 44: ......
Page 56: ......
Page 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Page 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Page 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Page 176: ......
Page 180: ......
Page 220: ......
Page 224: ......