2–14
Theory of Operation
2.3 SF7x Series Storage Enclosure
The SF7x storage enclosure connects its resident disk ISEs to the DSSI
bus in parallel. If one of the four drive positions is empty, that position
is ignored. If a position is occupied, the ISE can be on-line or off-line,
MSCP enabled or disabled, powered up or down, or failed. In any case,
the performance of the DSSI bus is not directly affected.
The storage enclosure provides termination power for the DSSI bus when
operating in either split-bus mode or through-bus mode.
2.3.1 DSSI Node ID
Four switchpacks behind the OCP door are used for setting the DSSI node
ID of the ISEs in the SF7x enclosure (Figure 2–5). The leftmost switch is
the MSCP enable switch, and must be set in the down position in order
for MSCP to be enabled. The other switches are used to set the DSSI
node ID, where the rightmost switch is the least significant.
Typical switch settings are shown in Table 2–5 and Table 2–6.
Table 2–5
DSSI ID Switch Settings (DSSI VAXcluster)
Disk ISE
DSSI
ID
Setting
1
Positions 1, 2, 3, 4, 7 and 8
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
1
2
3
4
001
010
011
100
1
‘‘0’’ = down, ‘‘1’’ = up.
Summary of Contents for EK-SFXXS-SG-003
Page 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Page 10: ......
Page 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Page 24: ......
Page 44: ......
Page 56: ......
Page 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Page 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Page 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Page 176: ......
Page 180: ......
Page 220: ......
Page 224: ......