SF7x Storage Enclosure FRU Replacement
6–41
Install the new drive dc power switch.
1. Install the new drive dc power switch into the enclosure frame.
2. Install all single-black, pigtail-black, and orange wires to all drive dc
power switches, observing the correct drive position.
3. Route all drive position power cables to the correct drive position.
NOTE
The left-rear and right-rear cables are 31.5 inches long. The
left-front and right-front cables are 15 inches long. Be sure to
route the correct cable to the correct drive position.
4. Install the protective cover over the drive dc power switches and
secure it with the two Phillips screws previously removed.
NOTE
Do not disturb the fingerstock on the storage enclosure frame.
WARNING—USE TWO PEOPLE.
The next step requires two people to lift the inner assembly
back into the extrusion tube mounted in the storage array.
5. Slide the inner assembly back into the extrusion tube. Secure the
front panel captive screws. Do not use excessive force as it may strip
the threads in the extrusion tube.
6. Tighten the four captive screws at each corner of the enclosure frame.
7. Replace the front and rear covers on the storage enclosure and tighten
the top two captive screws.
8. Replace the OCP by aligning the OCP connector pins with the TTM
clip fasteners on the transition-termination module. Push, do not
force, the OCP into the fasteners by applying equal pressure to both
sides.
9. At the rear of the storage enclosure, reconnect the ac power cord to
the ac receptacle on the power supply.
10. Replace the DSSI interconnect cables to the rear bulkhead of the
enclosure.
11. Restore the enclosure to service, and run the checkout procedure in
Section 6.8.
Summary of Contents for EK-SFXXS-SG-003
Page 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Page 10: ......
Page 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Page 24: ......
Page 44: ......
Page 56: ......
Page 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Page 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Page 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Page 176: ......
Page 180: ......
Page 220: ......
Page 224: ......