6–24
SF7x Storage Enclosure FRU Replacement
DRVTST is a comprehensive hardware test. Once invoked, it prompts you
to specify whether the test should be a write/read test or a read-only test.
After you specify the type of test, it runs for 5 minutes. After 5 minutes,
DRVTST indicates either that the test passed, or that a failure occurred.
Once the disk ISE has passed DRVTST, the installation is complete.
Example 6–6 shows how to run DRVTST.
NOTE
You may abort the test at any time by pressing one of the
following:
Ctrl/C
,
Ctrl/Y
, or
Ctrl/Z
. If you do abort the test, the
informational message
Operation aborted by user
is displayed.
Example 6–6
Running DRVTST
$ SET HOST/DUP/SERVER=MSCP$DUP/TASK=DRVTST R1EJAA
Copyright © 1989 Digital Equipment Corporation
Write/read anywhere on the medium? [1=Yes/(0=No)] 1
User data will be corrupted. Proceed? [1=Yes/(0=No)] 1
5 minutes to complete.
Test passed.
In Example 6–6, DRVTST is accessed through the VMS operating
system on a disk ISE with a node name of R1EJAA.
You must respond to this query for the program to continue. By
answering yes (1), you select a write/read test, and DRVTST prompts
you with another query.
In this case, type 1
Return
, selecting a write/read test.
This query gives you the chance to reconsider. If you answer no (0),
your response to the first query is overridden, and a read-only test
is executed. If you answer yes (1), DRVTST begins executing a write
/read test of the disk ISE.
In this case, type 1
Return
.
The program displays this message during the test.
Summary of Contents for EK-SFXXS-SG-003
Page 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Page 10: ......
Page 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Page 24: ......
Page 44: ......
Page 56: ......
Page 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Page 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Page 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Page 176: ......
Page 180: ......
Page 220: ......
Page 224: ......