3. Insert the other end of the BC16D cable into the cable concentrator
shown in Figure 11. Lock the connector in place by using the bail
latches.
Figure 11:
Connecting Devices to the Cable Concentrator
Concentrator
(Rear View)
Modified
Modular Jack
Bail
Latches
To Terminals
and Printers
BC16D Cable
H3104 Cable
Concentrator
(Front View)
H3104 Cable
MLO-002274
To System
4. Insert each printer and terminal cable into one of the modified modular
jacks on the cable concentrator as shown in Figure 11.
5. If you have not done so, connect the terminal or printer to the other
end of the cable. Your terminal or printer documentation shows how to
connect the cable.
If the printer or terminal does not have a modified modular jack
connection, use a passive adapter (H8575–A), available in 25-pin and
9-pin models.
Follow the same procedure for connecting a second BC16D cable to the
module, except insert the cable into the connector labeled 0–7.
You can mount the cable concentrator on a wall. Wall mounting keeps
cables off the floor. Use two screws as shown in Figure 12.
20
VAX 4000 Model 200 (BA430) Installation