Chapter 1 – PS-B Unit Basics
PS-2000B Series User Manual
1–10
1.4.3
DVI-D Interface
Pin No.
Signal Name
Pin No.
Signal Name
1
TMDS DATA2-
13
NC
2
TMDS DATA2+
14
NC
3
TMDS DATA2 SHIELD
15
GND
4
NC
16
Hot Plug Detect
5
NC
17
TMDS DATA0-
6
DDC Clock
18
TMDS DATA0+
7
DDC Data
19
TMDS DATA0 SHIELD
8
NC
20
NC
9
TMDS DATA1-
21
NC
10
TMDS DATA1+
22
TMDS CLOCK SHIELD
11
TMDS DATA1 SHIELD
23
TMDS CLOCK+
12
NC
24
TMDS CLOCK-
24-pin (Female)
Inch-type screws #4-40UNC
1
8
17
24
9
Connecting the FP-3700T
When connecting Pro-face’s FP-3700T to a PS-B unit using the FP-DV01-100<10m>
cable, be sure to change the dip switch settings on the PS-B unit’s main circuit board.
Refer to the following figure when changing the settings. For details about dip switch
positions, refer to
1.3 PS-B Part Names and Features
.
The factory settings for switches 1 to 4 are all OFF.
SW #4 : OFF
→
ON
* 1 When SW4 is ON and used together with a second RGB monitor, the screen
display resolution is fixed to XGA.
•
When using Pro-face’s FP Series, be sure to read that unit’s
User Manual prior to operation.
•
When using a DVI-D monitor together with a second RGB
monitor, some RGB monitors may not be able to be used, so
please include a monitor test in your system testing.
•
When using Pro-face’s FP-DV01-50<5m> cable, use this dip
switch’s default setting.
ON
OFF
Default
SW1
SW2
SW3
SW4
FP-3700T
*1
(with FP-DV01-100)
Different monitor
Reserved
All OFF
Reserved
Reserved
1 2 3 4
ON
OFF