30
Reference & Installation Manual
13
System Settings and Commands
13.1 Hardware Reset
A Hardware Reset sets sections
[0001]
to
[3991]
to default. Only the Panel
ID, PC Password, PC Telephone Number and Event Buffer are not reset.
The Installer Code Lock prevents Hardware Reset.
1.
Make sure the Installer Code Lock is disabled
2.
Press and hold the Reset and Aux buttons for 3 seconds
3.
The panel will be reset to defaults
13.2 Software Reset
Performing a software reset will set certain parameters to default values or
program certain sections with a set of pre-defined values. To reset:
1.
Enter
Panel Programming Mode
.
2.
Enter section
[4049]
to unlock software reset.
3.
Enter the 4-digit
[
SECTION
]
of the software reset you wish to perform.
4.
For every other section your want to reset, you will have to unlock
software reset.
Do not remove power from the control panel.
13.3 Installer Code Lock
S
ECTION
[3001]
(default =
000
) Enter 147 into section
[3001]
to lock all programming. When
147 is programmed, performing a hardware reset as described in
will not affect the current panel settings. To remove the Installer Lock,
enter 000 into section
[3001]
.
13.4 Daylight Savings Time
S
ECTION
[3030]: O
PTION
[3]
(default =
enabled
) When enabled, the control panel adjusts the system's
clock (time) for daylight saving changes.
13.5 Daylight Savings Time Schedule
S
ECTION
[3022]
(default =
18
)
Select the schedule followed for the Daylight Savings Time adjustment.
13.6 Battery Charge Current
S
ECTION
[3030]: O
PTION
[5]
Depending on the battery’s capacity, enable or disable the option:
A 40VA transformer is required when selecting the 850mA battery charge current, a
20VA transformer may damage the system.
13.7 Combus Speed
S
ECTION
[3030]: O
PTION
[8]
In large installations, set the speed to High. If you are experiencing
communication troubles, set the speed to Normal or install a Hub (APR3-
HUB2). The control panel will restart when a change is made
Please note that when the combus speed is changed the following
will occur and is considered normal operation:
• The message COMM. TROUBLE CALL SERVICE will be
displayed on keypads connected to the combus.
• The AC and STATUS LEDs will begin to alternately flash and all
operations on the system will be suspended for approximately
one minute while the system reconfigures.
13.8 Transmit Zone Status on Serial Port
S
ECTION
[3035]: O
PTION
[7]
When enabled, the control panel will transmit zone status information
through the serial port. Use this when there are devices or software
connected to the serial port like WinLoad.
13.9 Serial Port Baud Rate
S
ECTION
[3035]: O
PTION
[8]
Adjust depending on the baud rate set in WinLoad or NEware:
If communication between the control panel and the computer is
experiencing difficulty at 57,600 baud, especially over long
distances reduce the baud rate of the software to 38,400 baud.
[4040]
Resets the programmable sections from
[0001]
to
[3991]
to
default (even if Installer Code Lock is enabled) except: Event
Buffer, Panel ID, PC Password, PC Telephone Number and Zone,
Door, Partition and User Labels (see
[4041]
Resets the System Master Code to 123456.
[4042]
Resets all Zone Programming sections from
[0001]
to
[0196]
,
[0201]
to
[0296]
and
[0961]
to
[0984]
to default.
[4043]
Resets the Access Control sections, except Door Labels (see
[2201]
to
[2712]
to default.
[4044]
Resets all User Access Code Programming sections from
[1001]
to
[1999]
and
[2001]
to
[2199]
to default. User Labels (see
on page 34) will not be reset.
[4045]
Resets all control panel settings from
[3020]
to
[3043]
and from
[3900]
to
[3991]
and all the Dialer sections from
[3051]
to
[3081]
.
[4046]
Resets all Partition Settings, except Partition Labels (see
[3101]
to
[3831]
to default.
[4047]
Resets Keyswitch Programming sections from
[0501]
to
[0832]
and all Programmable Outputs sections from
[0901]
to
[0939]
to
default.
[4048]
Entering this section resets the User Labels from the User
Access Codes, the Zone Labels from
[0301]
to
[0396]
, Door
Labels from
[2301]
to
[2332]
, Partition Labels
[3100]
,
[3200]
,
[3300]
,
[3400]
,
[3500]
,
[3600]
,
[3700]
and
[3800]
to default.
[4049]
Entering this section will unlock software reset for sections
[4040]
to
[4048]
.
00
Canada/United States/Mexico/
St-Johns/Bahamas/Turks and
Caicos
01
Cuba
02
Brazil
03
Chile
04
Falkland Islands
05
Paraguay
06
European Union/United
Kingdom/Greenland
07
Russia and surrounding
countries
08
South Australia/Victoria/
Australian Capital Territory/
New South Wales
09
Tasmania/Lord Howe Island
10
New-Zealand/Chatham
11
Tonga
12
Iraq/Syria
13
Israel (TBC)
14
Lebanon/Kirgizstan
15
Palestine
16
Egypt
17
Namibia
18
Canada/United States 2007
(default)
19
New Zealand
[5]
ON
850mA
[5]
OFF
350mA (default)
[8]
ON
High Speed
[8]
OFF
Normal Speed (default)
[8]
ON
57,600 baud
[8]
OFF
38,400 baud (default)