background image

Specification List 

SM-100 V2.00 

26 December, 2006

 

2

nd

 R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.                                                                              11 of 32 

 

SPEC 

NO. 

SPECIFICATION DESCRIPTION 

SM-100 

 

 

 

 

 

 

154 

Keysheet Letter Size 

W

 

 

0 Small 

Letter 

1 Capital 

Letter 

For FL & AS only. 

 

 

 

 

 

 

 

 

 

155 

Test Print on Receipt 

W

 

 

0 No 

Print 

1 Print 

For SD only. 

 

 

 

 

 

 

 

 

 

156 

Image Copy from Free Format 

X

 

 

0 Disable 

1 Enable 

 

 

 

 

157 

Training Mode 

W

 

 

0 Disable 

1 Enable 

Exclude DEC. 

 

 

 

158 

FSD Price and Image 

W

 

 

0 Disable 

1 Enable 

For U1 only. 

 

 

 

 

 

 

159 

½ and ¼ Key Function 

W

 

 

0 Disable 

1 Enable 

 

 

 

 

160 

Twisted Pair Cable for Ethernet 

W

 

 

0 Shield 

1 Unshielded 

Not in used. 

 

 

 

 

 

 

 

 

 

161 

Discount Label Format 

W

 

 

0 Enable 

1 Disable 

For SD only. 

 

 

 

 

 

 

 

 

 

162 

Item Code Function Key Enable 

 

 

0 Enable 

1 Disable 

 

 

 

 

 

 

 

 

 

 

163 

Transaction Data Store in Client Memory

 

 

0 Disable 

1 Enable 

 

 

 

 

 

 

 

 

 

 

164 

Maximum Label Length 

W

 

 

0 120 

mm 

1 240 

mm 

 

 

 

 

 

 

 

 

 

 

165 

Update Report for Client / Server System

 

 

0 Yes 

1 No 

 

 

 

 

 

 

 

 

 

 

166 

Average Price and Weight Label Function

X

 

 

0 Disable 

1 Enable 

 

 

 

 

 

 

 

 

 

 

167 

Label Date Title Print 

X

 

 

0 No 

Print 

1 Print 

Exclude AA. 

 

 

 

 

 

 

 

 

 

168 

GB Code 

W

 

 

GB Code 

Shift GB Code 

For CN and MS only. 

 

 

 

 

 

 

 

 

 

169 

Print PLU Setting Unit in Manual Mode

 

 

0 No 

1 Yes 

 

 

 

 

 

 

 

 

 

 

170 

User Specification ( 141) Accessible from Z Mode Only

W

 

 

0 No 

1 Yes 

 

 

 

 

 

 

 

 

 

 

171 

Euro Mode 

X

 

 

0 Disable 

1 Enable 

 

 

 

 

 

 

 

 

 

 

172 

Dual Declarations 

X

 

 

0 No 

1 Yes 

For U1 only. 

 

 

 

 

 

 

 

 

 

173 

Mask 7-segment Display in X, S and Z Mode

W

 

 

0 No 

1 Yes 

For double display types 
only.  

 

 

 

 

 

 

 

 

 

174 

Fixed Clerk Assign to Preset Key 8, 16, 24 and 32

W

 

 

0 Clerk 

Keys 

1 Function 

Keys 

For bench type only. 

 
 

All manuals and user guides at all-guides.com

Summary of Contents for SM-100

Page 1: ...ary 2009 SHANGHAI TERAOKA ELECTRONIC CO LTD TECHNICAL SUPPORT DEPARTMENT 1rd Floor of 2nd Building Jia Yuan Business Center 51 Long Wu Road Shanghai China 200232 TEL 86 21 6408 5151 FAX 86 21 6408 3468 EMAIL ADDRESS steservice digi scale com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...Head 9 1 5 Features 10 1 6 Specification 11 1 7 Label Type 12 2 Initial Setup 13 2 1 Setup 13 2 2 Location of Switches and Connectors 15 2 3 Memory Initialisation 15 2 4 Default Specification Setting 16 3 Calibration 18 3 1 Calibration Operation 18 3 2 Exit Calibration 19 All manuals and user guides at all guides com ...

Page 3: ...stment of Printing Position 37 5 3 Voltage Checkpoint 38 6 Interface 39 6 1 PC Interface 39 6 2 Scale Ethernet Address 40 6 3 Scale IP Address 41 6 4 Connection Method 42 6 5 Wire Configuration 44 7 Miscellaneous 46 7 1 Mode Change 46 7 2 Span Switch Status 46 7 3 Clear All PLU Data 46 7 4 Thermal Head Usage 47 7 5 IP ADDRESS 47 All manuals and user guides at all guides com ...

Page 4: ...8 7 9 SERIAL NO 48 8 0 ASCII CHARACTER 49 8 Appendix A SpecificationList_V200 B FlexibleL Barcode Setting Guide C Traceability Setting Guide D Nutrition Setting Guide E PC FL1 Operation Guide F Circuit 9 Error Message All manuals and user guides at all guides com ...

Page 5: ...SM 100 GENERAL 1 1 GENERAL 1 1 OVERALL VIEW Bench Type Pole Type Elevated Type All manuals and user guides at all guides com ...

Page 6: ...SM 100 GENERAL 2 Bench CS Type Pole CS Type Hand Type All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 7: ...0 GENERAL 3 1 2 DISPLAY PANEL 25 digits 19 segments TN type LCD 32 202 full dot Matrix Green LCD 1 3 KEY PANEL Preset Keys Type B P 32 Preset keys 40Preset Keys All manuals and user guides at all guides com ...

Page 8: ...SM 100 GENERAL 4 56 Preset Keys Type PCS New PCS New 74 Preset Keys Type EV PCS Old 76 Preset Keys Type Hanging All manuals and user guides at all guides com ...

Page 9: ...nd Z Mode Item test print in S Mode CLEAR KEY C For Back space or Clear numeric value Select YES in S and Z Mode RE ZERO KEY Reset weight to ZERO PREPACK KEY AUTO Switch Manual mode and Pre pack mode alternatively The mode status will be indicated in the P and M indicator P PRE PACK MODE M MANUAL MODE CHANGE KEY Calculate the Changed Amount Escape the Programming screen without saving data in S Mo...

Page 10: ...ode Select Data Transaction Type in Z Mode CLERK KEY V1 V4 Accumulate the Total Price VOID KEY Correct the sales data PLU KEY PLU Call up PLU data in R Mode Store the programmed data in S Mode FEED KEY Feed Label or Receipt paper PRINT KEY Print out Label or Receipt Note BCS or PCS stands for the scale with cassette All manuals and user guides at all guides com ...

Page 11: ...hop name etc Indicator Z TOTAL MODE Clear sales data stored Indicator X Blink Password Setting Mode Set PASS WORD for X S Z mode set PASSWORD for PASSWORD MODE when all indicators R X S Z blink Decrease Increase Specification Count key Decrease Increase Only used when Setting SPEC 141 142 Select parameter data such as SPEC data Move cursor left or right 1 4 Thermal Printer Head Max Printing With 5...

Page 12: ...3000S 1 3000M 1 6000S 1 3000S 1 3000M 1 6000S Internal count 1 90000 Calibrating by software Customer and operator display optional customer pole display SM 100 25 digits x 19 segments TN type LCD with back light for numeric digit and character display SM 100 32 x 202 full dot Martix Green LCD display membrane keys a ON OFF key b 10 Numeric keys to key in numeric data c Preset keys to preset PLU o...

Page 13: ...digits Total price display 7 digits 1 6 2 Operating Conditions Power Source AC 110V 220V 10 15 50 60Hz Operating Temperature 10 C 40 C Operating Humidity 15 85 RH Power Consumption 70 W 1 6 3 Dimensions Platter size Bench Pole and Elevated 386 W x 270 D mm Bench CS and Pole CS 359 W x 277 D mm Hanging 274 d x 35 h mm Overall size a Bench 386 W x 415 D x 127 H mm b Pole 386 W x 478 D x 480 H mm c E...

Page 14: ...ore see diagram above If labels are wound wrongly printing problem may result We do not recommend the use of varnish labels Label Type Dimension mm T1 28 X 56 T2 31 X 56 T3 34 X 56 T4 40 X 56 T5 43 X 56 T6 46 X 56 T7 49 X 56 T8 55 X 56 T9 37 X 56 T10 40 X 56 T11 43 X 56 T12 49 X 56 S 28 X 37 A 46 X 37 B 46 X 37 C 62 X 37 F1 F99 Free Format All manuals and user guides at all guides com ...

Page 15: ...SM 100 INITIAL SETUP 13 2 INITIAL SETUP 2 1 SETUP Ü Indication of Assemble All manuals and user guides at all guides com ...

Page 16: ...14 Ü Bubble Adjustment Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the centre as shown above Bubble All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 17: ... turns on Rezero 2 3 0 CLEAR PLU FILE PLU file CLEAR VENDER DATA Vender transaction data CLEAR REPORT FILES Report files CLEAR MEMORY DATA All files in memory CLEAR MEMORY Y C N T C to clear file data T to quit C or T Z1 0 RESET SALES DAILY Return to Z mode Span Switch Power Switch Cash Drawer Port RS232 Port Ethernet Port Fuse Holder All manuals and user guides at all guides com ...

Page 18: ...kip C SCALE TYPE POLE Set scale type X SCALE TYPE BENCH X to select type to update type setting SCALE CAP 3KG Set scale capacity X SCALE CAP 6KG X to select capacity to update capacity setting SCALE RES 1 3000S Set resolution X SCALE RES 1 3000M X to select resolution to update resolution setting CLEAR MEMORY Y C N T C to clear memory T to skip C Z1 0 RESET SALES DAILY Return to Z mode Note 1 For ...

Page 19: ...es 17 AS Austria 58 LS Lesotho 18 DM Denmark 59 MU Mauritius 19 FL Finland 60 MW Malawi 20 NW Norway 61 MZ Mozambique 21 SD Sweden 62 NM Namibia 22 PG Portugal 63 RE Reunion 23 UK United Kingdom 64 SH Seychelles 24 IL Ireland Kg 65 SW Swaziland 25 IL LB Ireland Lb 66 WZ Zimbabwe 26 CA Canada Kg 67 ZW Zambia 27 CA LB Canada Lb 68 AE U A E 28 AG Argentina 69 TT Trinidad and Tobago 29 MX Mexico 70 UD...

Page 20: ...r Z mode 3 1 CALIBRATION OPERATION OPERATION DISPLAY REMARK PT kg kg Press SPAN SWITCH Z1 0 RESET SALES DAILY SPAN SWITCH is on ENABLE Rezero 8 7 1 5 CAL 00 Enter 8 7 1 5 while depressing Rezero Ensure no weight on platter Calibrating zero point After storing the zero Point IR count CAL SP Put full capacity weight on platter Calibrating Span After calibration Z1 0 RESET SALES DAILY Go back to Z mo...

Page 21: ...ter 8 7 1 5 while depressing Rezero T Z1 0 RESET SALES DAILY Escape to Z mode Lamp Z always light Rezero 8 7 1 5 CAL 00 The IR count will be taken as the zero point IR count After storing the zero Point IR count CAL SP Calibrating Span T Z1 0 RESET SALES DAILY Escape to Z mode Lamp Z always light All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 22: ...we add a new method to update the scale s software update the scale by ethernet So you can choose either method between these two ones to update your scale Now we will set two parts to introduce the steps of these two updating methods Æ Update Steps Introduction I Ethernet Update Method 1 Cable Connection There are also two ways to connect the PC and the scale in updating the scale by ethernet 1 P...

Page 23: ...ng Steps 1 How to start ethernet updating A Turn on the switch on the bottom of the scale B Power off the scale by pressing On Off Key C After that press and hold Re Zero and Preset 22 then start the scale by pressing the On Off Key D The screen will display the version of the current boot program for two seconds E Only in new versions version of the boot program newer than 1 10 you can choose 2 e...

Page 24: ...SM 100 SOFTWARE SETTING 22 3 How to upload the scale by Mini Programmer A Select SM 100 and press ok B Set the port Select ethernet and press OK All manuals and user guides at all guides com ...

Page 25: ...ogrammer Buffer Open the source file of boot program e g sm100bv100 hex You can see a speed mode select window here Select menu Flash Program Notice The message 001 scale ready update must be displayed on the screen of the scale before pressing the run button All manuals and user guides at all guides com ...

Page 26: ...e scale is updated from 1 xx to 2 xx firstly you must update the boot program of the version D Download main program file You must power off the scale and start the ethernet upload method again when you have finished a program uploading The steps of uploading the main program file is also like uploading the boot program file The file you need to open is like Pic 2 Pic 2 All manuals and user guides...

Page 27: ...am file The file you need to open is like Pic 3 Pic 3 F Download const text file The steps of uploading the const text file is also like uploading the boot program The file you need to open is like Pic 4 Pic 4 G Exit Mini Programmer Note please update the scale according to sequence above All manuals and user guides at all guides com ...

Page 28: ...ansmission between PC and SM 100 9 Pin D Sub Female Connectors for this cable PC Serial Port SM 100 RS 232C 9 Pin D Sub Female 9 Pin D Sub Female Pin Signal Signal Pin 1 N C N C 1 2 RXD RXD 2 3 TXD TXD 3 4 N C N C 4 5 GND GND 5 6 9 GND N C 6 9 All manuals and user guides at all guides com ...

Page 29: ... boot program for two seconds E Ü If the scale boot version is newer than 1 10 it will display a updating method choice like 1 RS232 2 ETHERNET on the screen you can press Numeric 1 to choose 1 RS232C Ü If the boot version is older than 1 10 the scale will not display the choice F Then the Scale will display PROGRAM You can t stop it unless you press Tare or On Off Key 2 Start Mini Programmer 1 Se...

Page 30: ...E SETTING 28 3 Download the boot program and update the scale Select menu File Load File To Programmer Buffer Open the source file of the boot program e g sm100bv100 hex All manuals and user guides at all guides com ...

Page 31: ...n the scale before pressing the run button After the transmission has completed select menu File Clear Buffer Notice If the boot program of this version is already in the scale you don t need to upload it again skip it and upload the main program All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 32: ...loading the boot program file The file you need to open is like Pic 2 Pic 2 5 Download word stock file The steps of uploading the word stock file is also like uploading the boot program file The file you need to open is like Pic 3 Pic 3 6 Download const text file The steps of uploading the const text file is also like uploading the boot program The file you need to open is like Pic 4 All manuals a...

Page 33: ...SM 100 SOFTWARE SETTING 31 Pic 4 7 Exit Mini Programmer All manuals and user guides at all guides com ...

Page 34: ...EC data 1 7 X SPEC 000 SPEC 017 017 XXX XXX XXX It goes to a designed specification count 000 441 is enabled SPEC 017 XXX XXX key select SPEC data Move cursor right SPEC 017 XXX XXX key select SPEC data Move cursor left 1 SPEC 017 SPEC 018 001 XXX XXX XXX C SPEC 018 000 XXX Clear the enter data PLU Note 1 Z1 0 RESET SALES DAILY Store the updated specification and escape to Z mode Remark The Weight...

Page 35: ... XXX XXX key select SPEC data Move cursor right SPEC 615 XXX XXX key select SPEC data Move cursor left 1 SPEC 615 SPEC 616 001 XXX XXX XXX key to update specification increase specification count 2 SPEC 616 002 XXX C SPEC 616 000 XXX Clear the enter data PLU Note 1 Z1 0 RESET SALES DAILY Store the updated specification and escape to Z mode Note 1 If press T key it does not store the updated specif...

Page 36: ...ADJUSTMENT 34 5 ADJUSTMENT 5 1 PEEL SENSOR VOLTAGE AND LABEL SENSOR SENSITIVITY ADJUSTMENT LOCATION OF PEEL AND LABEL SENSOR Label Sensor All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 37: ...abel paper peel sensor voltage window displays new setting value T Z1 0 RESET SALES DAILY T key to exit 5 1 2 Label Sensor Sensitivity When the label came out three or more when feeding or printing the sensitivity of the sensor need to be adjusted to sense the gap between the label better There is a variable resistor near the sensor Adjust it to increase or decrease the sensitivity Clockwise is to...

Page 38: ...ALES DAILY Z mode Lamp Z turns on Rezero 5 1 6 GAP PFD 2 0 3 1 Enter 5 1 6 while depressing Rezero kg window displays label paper gap sensor voltage window displays new setting value T Z1 0 RESET SALES DAILY T key to exit All manuals and user guides at all guides com ...

Page 39: ...setting 1 0 ADJ PFD 0 10 To move up the point position on label enter the new value by numeric key Ex 10 dots 1 0 ADJ PFD 0 10 If you want to move down the print position please enter the new value by numeric key Ex 10dots and then press key PLU 0 000 0 000 0 00 0 00 Save the feed setting T Z1 0 RESET SALES DAILY If you want to exit without saves the setting press T key to exit PRINTING TOO HIGH C...

Page 40: ...ltage points that are commonly use VOLTAGE POINT VOLTAGE PURPOSE VCC 3 3 V Provide voltage for most of the IC VTH 24 V Provide voltage mainly to the thermal head VBB 3 V Provide backup voltage for the RAM IC HVcc 5 V The tolerance of all the voltage is about 5 except VTH is 2 and 5 All manuals and user guides at all guides com ...

Page 41: ...k 255 255 255 0 Above IP address is use as a standard address to use for SM 100 Ethernet communication If whatever reason the IP address had to be change it may do so But the scale IP address had to be change at the SM 100 scale also so that they are within the same network Eg If the computer IP address is 192 168 1 XXX the SM 100 scale IP address has to be change to 192 168 1 XXX The last three d...

Page 42: ...the span switch before proceed KEY TO PRESS DISPLAY OPERATION PT kg kg Go to Z mode Z1 0 RESET SALES Daily At Z mode REZERO 0 6 1 2 ETHER NET Viewing of Ethernet address For new main board it can act as input of the address if the address shown Else it would not let you to input 0 0 0 6 C 0 0 0 0 0 2 4 ETHER NET 0006C 0000024 For input only Enter Ethernet address e g 0006C 0000024 PLU Z1 0 RESET S...

Page 43: ...lt is 192 168 000 000 where the last three digit will change when SPEC 135 change Please turn on the span switch before proceed KEY TO PRESS DISPLAY OPERATION PT kg kg Go to Z mode Z1 0 RESET SALES Daily At Z mode REZERO 0 4 1 6 SCALE IP Input or viewing of IP address 1 9 2 1 6 8 0 0 1 0 1 6 SCALE IP 192168 001016 Enter IP address e g 192 168 001 016 The last 3 digits cannot be input as it will ch...

Page 44: ...ber between 1 to 999 999 SPEC 51 Baud rate for SIO RS232C port 0 1200 2 4800 4 19200 1 2400 3 9600 5 38400 6 76800 SPEC 52 Data length for SIO For RS232C port 0 7 bit 1 8 bit SPEC 53 Parity for SIO For RS232C port 0 None 1 Odd 2 Even SPEC 54 Stop bit for SIO For RS232C port 0 1 bit 1 2 bits 6 4 2 Ethernet Connection Ethernet Interface Com 1 Com 2 RS232C Port All manuals and user guides at all guid...

Page 45: ...9 CLIENT SERVER INTERFACE 0 No interface 3 Not used 1 Ethernet Coaxial Cable 4 4 lines RS485 For future use 2 Ethernet Twisted Cable SPEC 50 CLIENT SERVER 0 Client 2 Back up server 1 Server Workstation SPEC 135 PORT NUMBER Enter number from 1 to 254 All manuals and user guides at all guides com ...

Page 46: ...ir 100MHz Cat 5 AWG 24 or 26 UTP FTP STP Preferable type Cat 5 AWG 24 or 26 FTP Cat 5 AWG 24 or 26 STP Recommended for CISPR 22B conformance PIN CONFIGURATION 1 8 SM 100 HUB 8 1 Solder to braid wire of the Ethernet wire if using plug without insert bar 1 8 SM 100 HUB 8 Solder the braid wire of the Ethernet 1 wire if using plug with insert bar STRAIGHT CONNECTION CROSSOVER CONNECTION SCALE HUB HUB ...

Page 47: ...onnector of Cash Drawer Pin Output Input Pin 1 Not used Not used 1 2 8 V Voltage 2 3 GDD GDD 3 4 Not used Not used 4 RS 232 PC Pin Pin 1 Not used Not used 1 2 RXD TXD 2 3 TXD RXD 3 4 DTR Not used 4 5 GND GND 5 6 DSR Not used 6 7 DTR Not used 7 8 DSR Not used 8 9 Not used Not used 9 RS232C Port 9 Pin PC COM Port 9 Pin 1 pin 4 pin 1 pin 4 pin All manuals and user guides at all guides com ...

Page 48: ...n When in Passwomode the indicator light will be blinking 7 2 SPAN SWITCH STATUS To check the status of the span switch OPERATION DISPLAY REMARK PT kg kg Go to Z mode Z1 0 RESET SALES DAILY Z mode Lamp Z turns on Rezero 2 8 4 STE16 VX XX S OFF Enter 2 8 4 while depressing Rezero Z1 0 RESET SALES DAILY Exit after 3 seconds 7 3 CLEAR ALL PLU DATA To clear all the PLU data only the span switch status...

Page 49: ...LES DAILY Z mode Lamp Z turns on Rezero 0 4 1 6 SCALE IP 19216800 0000 Display the scale IP address 1 9 2 0 0 9 1 0 0 SCALE IP 19200910 0000 Modify the IP address Save the new IP address Press T key to exit 7 6 SERVER IP ADDRESS To check and modify the server IP address OPERATION DISPLAY REMARK PT kg kg Go to Z mode Z1 0 RESET SALES DAILY Z mode Lamp Z turns on Rezero 0 4 1 7 SERVER IP 25525525 50...

Page 50: ...T SALES DAILY Z mode Lamp Z turns on Rezero 0 6 1 2 ETHERN ET 0006C071 96BE Display the MAC address T Z1 0 RESET SALES DAILY Press T key to exit 7 9 SERIAL NO To check the serial NO OPERATION DISPLAY REMARK PT kg kg Go to Z mode Z1 0 RESET SALES DAILY Z mode Lamp Z turns on Rezero 1 1 1 SCALE S N 05386686 Display the serial NO T Z1 0 RESET SALES DAILY Press T key to exit 8 0 ASCII CHARACTER Below ...

Page 51: ...5A a b c d e f g h i j k l m 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D n o p q r s t u v w x y z 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 0 1 2 3 4 5 6 7 8 9 30 31 32 33 34 35 36 37 38 39 21 40 23 24 25 5D 26 2A 28 29 3A 3B 22 27 2B 3C Space 3E 3D 2F 3F 2E 2C 20 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 52: ...2006 2 nd R D Dept SHANGHAI TERAOKA ELECTRONIC CO LTD 1 of 32 TITLE REVISION NO ISSUED DATE SM 100 SPECIFICATION LIST 0 17 August 2004 Rev No Modification Details Software Version 0 First Release 1 00 All manuals and user guides at all guides com ...

Page 53: ... SPEC1 1 03 Flag Data F1 and F2 for 13 Digits Non PLU Barcode X Enter value from range 0 to 99 04 Flag Data F1 and F2 for 13 Digits PLU Barcode X Enter value from range 0 to 99 05 Flag Data F2 for 8 Digit Non PLU Barcode X Enter value from range 0 to 9 06 Flag Data F1 and F2 for 8 Digit PLU Barcode X Enter value from range 0 to 99 07 Total Barcode X 0 F1F2 CCCCC XCD XXXX CD 12 F1X2 CCCCC XCD XXXX ...

Page 54: ...y and Year for Print X 0 MM DD YY 2 YY MM DD 1 DD MM YY 3 Not Used 18 1 or 2 Line s Commodity Name on Receipt X 0 2 Lines 2 No Print 1 1 Line 19 Label Printing by Clerk Key X 0 No Print 2 Print without Accumulated 1 Print with Accumulation 20 Total Label Printing X 0 No Print 1 Print 21 Printing Operator Name on Receipt and Label X 0 Code 1 Name 22 Receipt Paper Width W 0 60 mm 2 50 mm 1 40 mm 23 ...

Page 55: ... Enable 29 Continuous Print for Label in Prepack Mode X 0 Inhibit 1 Allow 30 Selection of CDV W 0 Inhibit 1 Allow For SF only 31 CDV Type W 0 CDV 1 Tear off For SF only 32 CDV Modulus W 0 Modulus 10 1 Modulus 11 For SF only Effective when SPEC30 and 31 1 33 On Spot Correction X 0 Allow 1 Inhibit 34 Search Correction W 0 Allow 1 Inhibit 35 Move Back Correction X 0 Allow 1 Inhibit 36 Past Sales Data...

Page 56: ...4 4 Lines RS 485 2 Ethernet Twisted Pairs 50 Setting of Client Server X 0 Client 2 Backup Server Related SPECs for S C setting are SPEC61 150 163 165 187 194 208 229 252 253 254 255 265 276 1 Server Workstation 51 Baud Rate of SIO RS 232C Port X 0 1 200 bps 4 19 200 bps Apply to both RS 232C and RS 485 ports setting for SM 300 Related SPECs are SPEC48 52 53 54 60 134 1 2 400 bps 5 38 400 bps 2 4 8...

Page 57: ... Allow 62 Receipt Free Format W 0 Disable 1 Enable Exclude AA 63 SM 90 and DI 10 RS 232C Communication W 0 No 1 Yes 64 Enable Password Mode X 0 Allow 2 Allow Multi Password 1 Inhibit 65 Report Printing in Daily and Term Transaction Clear X 0 Inhibit 1 Allow 66 Pack Quantity Function Key Enable X 0 Allow 1 Inhibit 67 Advertisement Function Key Enable X 0 Allow 1 Inhibit 68 Fixed Total Price Discoun...

Page 58: ...1 Unit Price Markdown 3 Unit and Total Price Markdown 84 Sub total Function Key Enable X 0 Allow 1 Inhibit 85 Grand Total Function Key Enable X 0 Allow 1 Inhibit 86 Label Sensor Gap Value W Enter value range from 0 to 255 87 Label Type X 0 Gap 1 No Gap 88 Sell by Date Title Print out W 0 Inhibit 1 Allow For AA only 89 ASCII Code Entry in S Mode W 0 Inhibit 1 Allow For AA only 90 Sub total Markdown...

Page 59: ... 1 Original Unit Price and Price 103 Unit Price Assignment Function Key for PLU 0 Enable 1 Disable 104 Discount Price Rounding Method X 0 Rounding 2 Cut Up 1 Cut Down 105 Fixed Total Price Markdown Function Key Enable X 0 Allow 1 Inhibit 106 Total Price Percentage Markdown Function Key Enable X 0 Allow 1 Inhibit 107 Fixed Unit Price Markdown Function Key Enable X 0 Allow 1 Inhibit 108 Fixed Unit P...

Page 60: ...r Printout W 0 Thick Character 1 Thin Character For AA only 122 Prepare Mode after Power On W 0 Manual Mode 1 Prepack Mode Always set to 0 for SM 200 123 Printing Thank You Message on Receipt W 0 Enable 1 Disable 124 PLU Unit Price after Discount X 0 Unit Price after Discount 1 Unit Price Discount Amount 125 Position of Special Message on Receipt X 0 Bottom 1 Top 126 Function Keys Protection for S...

Page 61: ...at X 0 YY 1 YYYY 142 Selection of Day Display for Sell by Date X 0 Disable 1 Enable 143 Peel Sensor Trigger Voltage W 0 High 1 Low 144 Display Prepack Quantity Balance W 0 Enable 1 Disable 145 Print Select Function Across the Board X 0 Disable 1 Enable 146 Label Format 1 2 Function Key Enable X 0 Inhibit 1 Allow Exclude AA 147 Prepack Non add Function Key Enable 0 Inhibit 1 Allow Exclude AA 148 FI...

Page 62: ...Function Key Enable 0 Enable 1 Disable 163 Transaction Data Store in Client Memory 0 Disable 1 Enable 164 Maximum Label Length W 0 120 mm 1 240 mm 165 Update Report for Client Server System 0 Yes 1 No 166 Average Price and Weight Label Function X 0 Disable 1 Enable 167 Label Date Title Print X 0 No Print 1 Print Exclude AA 168 GB Code W 0 GB Code 1 Shift GB Code For CN and MS only 169 Print PLU Se...

Page 63: ...rint 1 Print Effective when SPEC158 1 185 Weigh PLU Can Use for Non weigh PLU and Vice Versa Function Key Enable 0 Disable 1 Enable 186 Print and Weight Unit on Label X 0 No Print 1 Print 187 Clear Total Data by Server 0 Both Server and Client 1 Server 188 Tare Decimal Point Left Shift for SM 25 FIS3D W 0 No 1 Yes 189 PLU Auto Delete 0 No Delete 2 30 Days 1 15 Days 3 90 Days 190 Swap Weight and Un...

Page 64: ...reset Keys Pages X 0 1 Page 2 3 Pages by Shift Key 1 3 Pages by Toggle 204 Reference PLU Function Key Enable 0 Inhibit 1 Allow 205 Print Function Key Enable W 0 Inhibit 1 Allow 206 Print Barcode when Right Side Data Overflow 0 No print 1 Print Barcode Digits 207 Weight Decimal Point Position for Barcode and Label Printing W 0 Same as SPEC607 1 0 000 Effective when SPEC607 2 208 Network Time Out X ...

Page 65: ...th Tax Information Function Key Enable W 0 Inhibit 1 Allow 222 Open Cash Drawer without Sales Function Key Enable X 0 Inhibit 1 Allow 223 Negative Unit Price Function W 0 Disable 1 Enable 224 FIS3000 Wire Type W 0 4 wires 1 2 wires 225 Prepack Grand Total for Individual PLU 0 Yes 1 No 226 Reverse Calculation of ITF Check Digit X 0 No 1 Yes 227 Unit Price Override Password Function 0 Inhibit 1 Allo...

Page 66: ...Digits 242 Discount without Limit Function Key 0 Inhibit 1 Allow 243 Concatenate Commodity Name Display W 0 No 1 Yes 244 Enable PLU Price Change Flag 0 No 1 Yes 245 Print Sell by Date or Used by Date when Date Equals Packed Date X 0 Yes 1 No 246 Print First and Check Digits Outside Barcode X 0 No 1 Yes 247 Print Packed date X 0 Manual and Prepack Mode 2 Prepack Mode 1 Manual 3 No Print 248 Print S...

Page 67: ...de 1 Name 261 External Rewinder 0 Disable 1 Enable 262 Selection of Receipt Label W 0 Label 1 Receipt Always set to 1 for SM 200 263 FSD Net Value Minimum W 0 Off 1 On For U1 only 264 Print Ingredient Data on Next Label X 0 Disable 1 Enable 265 Client Using Local Free Format Label 0 No 1 Yes 266 FSD Weight W 0 Back Computed Single Range 2 Exact Weight For U1 only 1 Back Computed Dual Range 267 CPD...

Page 68: ...able 3 By Date and Reference No 1 By Reference No 4 By Date and PLU No 2 By PLU No 279 U1 Self service W 0 Disable 1 Enable For U1 only 280 Real Time Customer Number 0 No 1 Yes 281 Real Time Buffer Receipt W 0 Detail 1 Total Only 282 Barcode Function W 0 Without CR 1 With CR 283 Barcode Look up table LUT Contents W 0 Non weigh Item Only 1 All Items 284 Open Cash Drawer on Credit Payment X 0 Allow ...

Page 69: ...only 297 Print PLU Ingredient in Receipt W 0 No 1 Yes 298 Traceability Update Function 0 No 1 Yes 299 Keyboard Selection W 0 Normal Keyboard 2 80 Preset Keys 32 56 Preset Keys Identical to SPEC672 1 100 Preset Keys 300 SM 500 Self Service W 0 No 1 Yes 96 Preset Keyboard Identical to SPEC688 301 Print Receipt after Accumulation X 0 Yes 1 No 302 Fixed Port Number for Ethernet Enter value from 1 to 2...

Page 70: ... Yes 1 No 317 Wireless Communication X 0 No 1 Yes 318 Wireless FTP Port Number Enter value range from 1 to 9999 Not in used 319 Delete Traceability Record X 0 Yes 1 No 320 PLU Link to Text Field 0 Disable 1 Enable 321 Julian Date for Packed and Sell Date W 0 No 1 Yes For U1 only 322 Price Printing Size Large Font 0 No 1 Yes 323 Auto PLU Broadcasting 0 Disable 1 Enable 324 Decimal Point For Unit Pr...

Page 71: ...d 5 F5 1 F1 6 F6 2 F2 7 F7 3 F3 8 F8 4 F4 338 Traceability Barcode 0 EAN13 1 EAN128 339 Flag Data EAN13 Enter range from 0 to 99 340 Enforce Scan 0 No 1 Yes 341 TVP2000 SM300 0 Not Send T10 1 Send T10 Label Format 342 LCD 1 Line Scroll 0 Disable 1 Enable 343 Clear Key in Prepack 0 Enable 1 Disable 344 Print Pack Date 0 Yes 1 No 345 Update Spec For Server Client System 0 Enable 1 Disable 346 Update...

Page 72: ...r 2006 2 nd R D Dept SHANGHAI TERAOKA ELECTRONIC CO LTD 21 of 32 SPEC NO SPECIFICATION DESCRIPTION SM 100 350 Additional Rounding In Receipt 0 Print 1 No Print 351 Gratuitous ARP 0 Disable 1 Enable All manuals and user guides at all guides com ...

Page 73: ...Message on Receipt X 0 Allow 1 Inhibit 408 One or Two Touch for Receipt Printing in AMT TEND X 0 One Touch 1 Two Touch 409 PLU Number Printing on Receipt X 0 Inhibit 1 Allow 410 Sale Item Entry Method X 0 Total 1 Item 411 Default Vender Transaction by Print Key X 0 Allow 1 Inhibit 412 Print Checking Line X 0 Print 1 No Print 413 Source of Used by Date X 0 Current Date 1 Packed Date 414 In Store Ba...

Page 74: ...eceipt and Label 426 Print Tare Weight when Unit Price is 0 X 0 Allow 1 Inhibit 427 Eliminate Cash Line on Receipt when No change Operation X 0 Allow 1 Inhibit 428 PRINT Tax List on Receipt X 0 Allow 1 Inhibit Effective when SPEC603 1 429 Non Weigh PLU Unit Price Display X 0 Total Price Column 1 Unit Price Column 430 Items on PLU Main Group Dept Tax Report X 0 Registered Items 1 All Items 431 Elim...

Page 75: ... for Auto PLU Calling X 0 No 2 2 Digits Effective when Spec39 1 Spec40 0 1 1 Digit 3 3 Digits 444 Decimal Point Position for Second Currency X 0 None 2 0 00 1 0 0 3 0 000 445 Unit Price Change for PLU after Label Printing X 0 Inhibit 1 Allow 446 Print Tare Weight on Receipt 0 Allow 1 Inhibit 447 Place Change for PLU after Label Printing X 0 Inhibit 1 Allow For KE only 448 Sell Date Change for PLU ...

Page 76: ...tion X 0 Inhibit 1 Allow For U1 only 457 CN Weight Trace function X 0 Inhibit 1 Allow For CN only 458 CN Weight Quota function X 0 Inhibit 1 Allow For CN only 459 Symbol Format for Date Print X 0 Dash 1 Period 460 CN Weight Trace Password X 0 Inhibit 1 Allow For CN only 461 Unit and Currency Symbol for each line in Receipt X 0 Inhibit 1 Allow For U1 only 462 1000 Separator for total line print on ...

Page 77: ... Position for Weight X 0 None 2 0 00 1 0 0 3 0 000 608 Zero Point Setting Range when A C Display Switch On X 0 10 of Capacity 2 3 of Capacity 1 5 of Capacity 3 2 of Capacity 609 Decimal Point for Unit Price and Total Price X 0 None 2 0 00 1 0 0 3 0 000 610 Unit Price Decimal Right Shift W 0 Inhibit 1 Allow 611 Unit Price Decimal Left Shift W 0 Inhibit 1 Allow 612 Switching of Price Base X 0 Inhibi...

Page 78: ...n during Tare X 0 Allow 1 Inhibit 624 Zero Tracking during Tare X 0 Allow 1 Inhibit 625 Accumulation when Tare X 0 Allow 1 Inhibit 626 Digit Tare X 0 Allow 1 Inhibit 627 Decimal Point Figure X 0 Period 1 Comma 628 Price Rounding Method for Decimal Digits on Weighed Item X 0 Rounding 2 Cut Up 1 Truncating 629 Additional Price Rounding Method for Item Price X 0 No Addition Rounding 4 Rounding for 1s...

Page 79: ...s Weight is Equal Zero X 0 Inhibit 1 Allow Effective when SPEC640 0 642 Tare Display for One Touch Tare W 0 Allow 1 Inhibit 643 Weight Range for Non weigh Item X 0 Only Net 0d 1 Always 644 Weight Stability Condition X 0 Loose 2 Tight 1 Normal 3 Stringent 645 Weight Range for R Mode Printing X 0 Over Net 5d and Over Gross 21d and Weight Stability 2 Over Net 19d and Weight Stability 1 Over Net 1d an...

Page 80: ... 659 Item Price Printing W 0 Item Price before Tax 1 Item Price after Tax 660 Barcode Check Line X 0 Print 1 No Print 661 Additional Price Rounding Method for Total Price X 0 No Addition Rounding 4 Rounding for 1 st Digit 1 Rounding 25 step 5 Truncate 1 st Digit 2 Special Rounding 5 step 6 Cut Up 1 st Digit 3 5 Floor Rounding 0 4 0 5 9 5 662 Unit Price Recalculation W 0 Inhibit 1 Allow 663 Nordic ...

Page 81: ...de Data Shifting for Item and Total Barcode X 0 No 3 Left Shift Twice left shift valid for quantity only 1 Right Shift Once 4 Left Shift 3 Times 2 Right Shift Twice 5 Left Shift Once 677 Manual Weight Function Key X 0 Disable 1 Enable 678 Printing of Item Label after Weight Change W 0 Inhibit 1 Allow For SS type Effective when SPEC640 and 641 1 679 Catty Kati and Tael W 0 Disable 1 Enable Availabl...

Page 82: ...88 SM 500 Self service W 0 No 1 Yes 689 Consecutive Display W 0 1 Sec Stop 2 4 Sec Stop 1 2 Sec Stop 3 6 Sec Stop 690 Test Program W 0 Disable 1 Enable 691 One Touch Tare W 0 Enable 1 Disable 692 RESERVED W 693 Flexi Self Service Key Grouping X 0 No 1 Yes 694 Weight Hold Function W 0 Disable 1 Enable 695 Clerk Password Setting X 0 Disable 1 Enable For CA only 696 Quantity Symbol Re calculation W 0...

Page 83: ...n Price X 0 Rounding 2 Cut Up 1 Truncation 705 Commodity Name Display When Call PLU in Label Mode X 0 Allow 1 Inhibit 706 Commodity Name Display When Call PLU in Receipt Mode X 0 Allow 1 Inhibit 707 Price Fix X 0 Inhibit 2 Via FIX Key 1 Allow 708 Tare Fix X 0 Inhibit 2 Via FIX Key 1 Allow 709 Printing of Item Label Condition in Prepack Mode X 0 Weight Change More than 10e 1 Remove Weight 710 Net G...

Page 84: ...Enter item code length Press S46 3 F BAR 0 DATA1 Enter data format for DATA1 0 for weight 1 for quantity 2 for unit price 3 for weight quantity 4 for total price 5 for original price 6 for user programmable Press S46 4 F BAR 0 DIGIT Enter DATA1 length Press S46 5 F BAR 0 SHIFT Shift for DATA1 0 for no right shift 1 for right shift 2 for right shift x2 3 for left shift 4 for left shift x2 5 for lef...

Page 85: ...r left shift x2 5 for left shift x3 Press S46 9 F BAR NO MIDDLE CD Press to select the middle check digit Press S46 1 F BAR NO LAST CD Press to select the last check digit Press S46 1 F BAR ITF BARCODE Press to swith ITF and EAN barcode Press S46 FLEXI BARCODE Save the flexible barcode 1 Note See the Flexible Barcode Usage Note at 3 6 1 PLU programming in SM 100 Operation manual All manuals and us...

Page 86: ... SET Program country No 1 C H I N A S34 1 COUN CHINA Name 5 Program country name CHINA S34 å COUNTRY FILE Save Country No 1 3 5 S35 å CUTTING HALL Enter cutting hall programming 1 S35 0 HALL 1 NO SET Program cutting hall No 1 1 S35 1 HALL 1 COUNTRY Program cutting hall country No 1 C U T S35 2 HALL CUT Name 3 Program cutting hall name CUT S35 å CUTTING HALL Save cutting hall No 1 All manuals and u...

Page 87: ...name SLAUG S36 å SLAUGHTER HOUSE Save slaughter house No 1 4 7 S47 å KIND FLIE Enter kind file programming 1 S47 0 KIND 1 NO SET Program kind file No 1 M E A T S47 1 KIND MEAT NAME 4 Program kind name MEAT S47 å KIND FILE Save kind file No 1 4 8 S48 å CATEGORY FILE Enter category file programming 1 S48 0 CATEG 1 NO SET Program category No 1 B E E F S48 1 CATEG BEEF NAME 4 Program category name BEE...

Page 88: ...y programming 1 S37 0 TRACE 1 NO SET Program traceability No 1 1 S37 1 TRACE 1 BORN Choose born country No 1 1 S37 2 TRACE 1 FATTEN Choose fatten country No 1 1 S 37 3 TRACE 1 S HOUSE Choose slaughter house No 1 1 S37 4 S CNT 1 LNK 1 Choose link country No 1 for slaughter house 1 S37 5 TRACE 1 C HALL Choose cutting house No 1 1 S37 6 C CNT 1 LNK 1 Choose link country No 1 for cutting hall 1 S37 7 ...

Page 89: ...EED Choose breed No 1 C O N T S37 14 CONT CONT NAME 4 Program cont content CONT 0 6 0 3 1 0 S37 15 TRACE 060310 EAT D Program eat by date 06 03 10 5 0 0 0 S37 16 TRACE 5 000 WEGHT Program maximum weight 5kg S C D S37 17 S CD SCD NAME 3 Program S CD content SCD S N M S37 18 S NM SNM NAME 3 Program S NM content SNM S A D 1 S37 19 S AD1 SAD1 NAME 4 Program S AD1 content SAD1 S A D 2 S37 20 S AD2 SAD2...

Page 90: ...nter S19 å PLU ITEM press Ü Set Item TRACE to PROGRAM and press to save PLU Programming Ü When you edit PLU set S1 64 PLU to TRACE ALLOW and press Ü Input traceability number and press to save Ü In the end when you call the PLU and print label you ll see the traceability information on the label All manuals and user guides at all guides com ...

Page 91: ...nt 10 images 5 Enter S1 PLU FILE to create PLU 6 Enter S1 50 PLU 0 IMAGE 1 to choose the template number for IMAGE 1 From No 70 No 81 7 Enter S1 59 PLU 0 IMAGE 10 to choose the template number for IMAGE 10 From No 70 NO 81 8 Set S1 81 PLU PRINT NUTRI to set nutrition print status to Print 9 Enter from S1 82 to S1 10 to input nutrition contents 10 For extra details on the Nutrition Fact Enter S11 T...

Page 92: ...M series expect the SM 100 The link of the hardware Link the PC with scale via RS232C Operation 1 The Spec setting in the scale 3 for SPEC51 The SIO baud rate is 9600 1 for SPEC52 The SIO data length is 8 0 for SPEC53 No SIO parity digit 0 for SPEC54 1 bit stop bit 2 for SPEC60 SIO work via PCFL 1 2 The setting in the software 1 open the software All manuals and user guides at all guides com ...

Page 93: ...6408 5151 Fax 86 21 6408 3468 E Mail steservice digi scale com 2 the com port setting Please note a The com port should be the same as the one used in your computer b The com port setting must be same as setting in the scale 3 the folder for save All manuals and user guides at all guides com ...

Page 94: ...nical Support Dept Tel 86 21 6408 5151 Fax 86 21 6408 3468 E Mail steservice digi scale com Note You could set the default folder for save the data received from the scale 3 Operation 1 receive the data from the scale All manuals and user guides at all guides com ...

Page 95: ...he data to scale Note You could press the key to send the data to scale 2 the operation in the scale Operation Display Remark Weight Unit price Price Z M 0 M M DAILY 0 CLR X Enter the Z mode zero 0 1 0 BAC PLU FILE X Press preset key 7 or 8 to select the transmit item PLU Format Others or All Preset key 8 BAC FOR FILE X Preset key 8 BAC OTH FILE X Preset key 8 BAC ALL FILE X All manuals and user g...

Page 96: ... key 7 or 8 to select the transmit method save data to FL 1 read data from FL 1 verify data with FL 1 Preset key 8 BAC RD FR FL 1 X Preset key 8 BAC COMP FL 1 X T OUT OPN GOOD X Transmit successfully Tare DAILY 0 CLR X Back to Z mode Jasonzhou Shanghai Teraoka Electronic Co Ltd Technical Service Dept Dec 7th 2005 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 97: ...em Unit price weight or quantity is 0 24 WEIGHT OF Weight over maximum capacity when print 26 TOTAL PRICE OVERFLOW Total price over the limit to display or print 29 PLEASE SET TARE VALUE When force tare is enable a tare weight must be entered 39 PLEASE PRESS PLU KEY Press PLU key To save data in some procedure 44 KEY ALREADY ASSIGNED Preset key already been assigned with function or PLU 48 PLU DAT...

Page 98: ...nal flash memory erase error F003 External flash memory program error F004 External flash memory program error F005 Internal RAM read write error F006 External RAM read write error F007 External ethernet IC read write error All manuals and user guides at all guides com ...

Reviews: