Specification List
SM-100 V2.00
26 December, 2006
2
nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 5 of 32
SPEC
NO.
SPECIFICATION DESCRIPTION
SM-100
41
Unit Price of Weigh PLU Can Use for Price of Non-weigh PLU and Vice Versa
X
0 Allow
1 Inhibit
Effective when SPEC643
= 0.
42
Unit Price Override
X
0 Allow
1 Inhibit
43
Main Usage for Commodity Name, Shop Name and Special Message
X
0 Receipt
1 Label
Always set to 0 for SM-
200.
44
Tare Override
X
0 Allow
1 Inhibit
45
Item Printing
X
0 Allow
1 Inhibit
46
Default Data of Printing Shop Name Number for Label
X
Enter value from range 0 to 32
47
Default Data of Printing Shop Name Number for Receipt
X
Enter value from range 0 to 32
48
Setting of Scale Number
X
Enter value from range 0 to 999 999
49
Type of Client / Server Interface
X
0 No
Interface
3 Not
Used
Related SPECs for
Ethernet I/F are
SPEC50, 135, 214.
1
Ethernet (Coaxial Cable)
4
4-Lines (RS-485)
2
Ethernet (Twisted Pairs)
50
Setting of Client / Server
X
0
Client
2
Backup Server
Related SPECs for S/C
setting are SPEC61, 150,
163, 165, 187, 194, 208,
229, 252, 253, 254, 255,
265, 276.
1
Server / Workstation
51
Baud Rate of SIO (RS-232C Port)
X
0
1 200 bps
4
19 200 bps
Apply to both RS-232C
and RS-485 ports setting
for SM-300.
Related SPECs are
SPEC48, 52, 53, 54, 60,
134.
1
2 400 bps
5
38 400 bps
2
4 800 bps
6
76 800 bps
3
9 600 bps
52
Data Length of SIO (RS-232C Port)
X
0 7
Bits
1 8
Bits
Apply to both RS-232C
and RS-485 ports setting
for SM-300.
53
Parity Bit of SIO (RS-232C Port)
X
0 None
2 Even
Apply to both RS-232C
and RS-485 ports setting
for SM-300.
1 Odd
54
Stop Bit of SIO (RS-232C Port)
X
0 1
Bit
1 2
Bits
Apply to both RS-232C
and RS-485 ports setting
for SM-300.
55
Baud Rate of Multi-drop SIO (RS-485 / 4-Lines Port)
W
0
1 200 bos
3
9 600 bps
Related SPECS are
SPEC48, 56, 57, 58, 59,
134.
1
2 400 bps
4
19 200 bps
2
4 800 bps
5
38 400 bps
56
Data Length of Multi-drop SIO (RS-485 / 4-Lines Port)
W
0 7
Bits
1 8
Bits