AT commands
Output Control
XBee Wi-Fi RF Module User Guide
172
Q4 (Set time to hold DIO14)
Specifies how long pin P4 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Sets how long an output level programmed by bit 14 of the IO command is held in the selected state
before reverting to its configured level. See
for a functional description.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
Q5 (Set time to hold DIO15)
Sets how long an output level programmed by bit 15 of the IO command is held in the selected state
before reverting to its configured level. See
for a functional description.
Note
This option is available on the SMT module, but not the TH module.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
Q6 (Set time to hold DIO16)
Sets how long an output level programmed by bit 16 of the IO command is held in the selected state
before reverting to its configured level. See
for a functional description.
Note
This option is available on the SMT module, but not the TH module.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
Q7 (Set time to hold DIO17)
Sets how long an output level programmed by bit 17 of the IO command is held in the selected state
before reverting to its configured level. See
for a functional description.
Note
This option is available on the SMT module, but not the TH module.
Parameter range
0 - 0x1770 (x 100 ms)