Configure the XBee Wi-Fi RF Module using Digi Remote Manager
Transparent mode data
XBee Wi-Fi RF Module User Guide
95
4. Under
<requests>
, you can type a target name as desired, but any target name beginning with
XBee
(case insensitive) is reserved for use on the XBee device itself and will not be sent out the
serial port.
5. Type the string that will be output in the device request. Both the target name and the device
request string depend on your application and the XBee device passes these strings on,
unmodified.
6. In the
HTTP Method
field, select the
POST
option button.
7. Click
Send
. The device response appears in the
Web Services Responses
pane.
Transparent mode data
The XBee Wi-Fi RF Module also supports Remote Manager transmissions and receptions in
Transparent mode. Transparent data is sent to Remote Manager using the Send Data interface and
Transparent data is received from Remote Manager using the Device Request interface. Some parts
of those interfaces are lost due to not using the API interface.
Send data to Remote Manager
The device can send serial data to Remote Manager as files or as binary data points. To make this
selection, use bit 4 of
. If you set
DO
bit 4, then the serially-connected host sends
Transparent data to Remote Manager as binary data points. Otherwise, it sends the data as a file.
Files are static and permanent. Data streams are dynamic and you can graph them to understand
changes.
AT command settings to put serial data in Remote Manager
command:
0: Transparent Mode
1: API Mode without escapes
2: API Mode with escapes
command:
The URL for Remote Manager must be my.devicecloud.com or devicecloud.digi.com
command: