![Digi S6B User Manual Download Page 96](http://html.mh-extra.com/html/digi/s6b/s6b_user-manual_2496668096.webp)
Configure the XBee Wi-Fi RF Module using Digi Remote Manager
Transparent mode data
XBee Wi-Fi RF Module User Guide
96
Bits 0-7: Encoded in Hex.
0: Enable Remote Manager (1), Disable (0).
1: Soft AP when
ID
= None. This has nothing to do with Remote Manager.
2: Send Transparent Data to Remote Manager (1), send to
DL
(0).
3: Send
IO
both to Remote Manager and
DL
(1), Remote Manager only (0).
4: Send Transparent data as a data stream (1), file data (0) – must have bit 2.
5: If bit 4 is 0, replace file (1), append to file (0).
Hence, the following values:
00: Do not use Remote Manager at all.
05: Send Transparent data to Remote Manager as a file which is appended (00000101).
/ws/FileData/~/00000000-00000000-00409DFF-FFxxxxxx/serial/0
25: Send transparent data to Remote Manager as a file which is overwritten (00100101)
/ws/FileData/~/00000000-00000000-00409DFF-FFxxxxxx/serial/0
15: Send transparent data to Remote Manager as a data point – encoded in BINARY
/ws/v1/streams/inventory/00000000-00000000-00409DFF-FF5DB54F/serial/0
/ws/DataPoint/00000000-00000000-00409DFF-FF5DB54F/serial/0
/ws/DataStream/00000000-00000000-00409DFF-FF5DB54F/serial/0
01: Connect to Remote Manager, but send Transparent data to the address and port of
DL
/
DE
using
the protocol in IP.
This is convenient if you want to use the TCP or UDP method for posting at datapoint.
Send files
The file name that is written on Remote Manager is named
serial/0
. The file type is
text/plain
.
bit 5 selects whether to append to an existing file or to replace it. If replacing an
existing file and the size of the data being sent exceeds the maximum frame size allowed (1400
bytes), then that frame isbroken up and only the last part shows up in the file because the last part
will replace rather than append to the first part.
Send binary data points
To send binary data points to Remote Manager in Transparent mode: set
to 0x15
or 0x17, which means:
n
Set
DO
to bit 4.
n
Set
DO
bit 0 to enable Remote Manager.
n
Set
DO
bit 2 so Transparent data goes to Remote Manager.
To view the files:
1. Double click the device.
2. Click
Home
.
3. Click the
View Device Streams
button.
or
1. Click
Data Services
>
Data Streams
.
2. In the
Stream
column, click the MAC address of the module/serial/0.