AT commands
Output Control
XBee Wi-Fi RF Module User Guide
171
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
Q0 (Set time to hold DIO10)
Sets how long an output level programmed by bit 10 of the IO command is held in the selected state
before reverting to its configured level. See
for a functional description.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
Q1 (Set time to hold DIO11)
Sets how long an output level programmed by bit 11 of the IO command is held in the selected state
before reverting to its configured level. See
for a functional description.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
Q2 (Set time to hold DIO12)
Sets how long an output level programmed by bit 12 of the IO command is held in the selected state
before reverting to its configured level. See
for a functional description.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
Q3 (Set time to hold DIO13)
Sets how long an output level programmed by bit 13 of the IO command is held in the selected state
before reverting to its configured level. See
for a functional description.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0