Default
N/A
TP (Temperature)
Displays the temperature of the XBee Wi-Fi RF Module in degrees Celsius. The temperature value is
displayed in 8-bit two’s compliment format. For example,
0x1A
= 26 °C, and
0xF6
= -10 °C.
Parameter range
-30 to 85 °C
Default
N/A
CK (Configuration Code)
Reads the configuration code associated with the current AT command configuration.
Parameter range
2 bytes
Default
N/A
%V (Supply Voltage)
Displays the supply voltage of the device in mV units.
Parameter range
3.1 to 3.5 V
Default
N/A
LM (Link Margin)
Reads the received signal strength (RSSI) in terms of dB units above sensitivity and reports 0xff until
the first reception after connection to access point.
Parameter range
0 - 0xFF
Default
N/A