Rainwise Inc PVMET-100-2 Version: 1.1 Build 001 Jun 17
Modbus Device Address:
MBID
Description:
The Modbus device address can be viewed or changed using this
command. The default is address is 60
Values:
?,1 - 255
Syntax (Read):
MBID=?
Syntax (Write):
MBID=60
Sample Read Response:
60
Sample Write Response:
OK
Serial Number:
SERIAL
Description:
The serial number of the device can be viewed or changed using
this command. The serial number string is returned in SunSpec Common block.
Values:
?, character string (31 character limit)
Syntax (Read):
SERIAL=?
Syntax (Write):
SERIAL=ABC123
Sample Read Response:
ABC123
Sample Write Response:
OK
Command Mode:
EXIT
Description:
Exits from the command mode. Modbus is not functional in
command mode.
Values:
None
Syntax:
EXIT