VECTORDRIVE DSV 5444
Top technology in drive electronics
07.07.04 10:12
Dietz-electronic
page 37 of 60
Address
Name
RW
Explanation
standard: 792h = 2 corresponds to 10 mV)
EB2h
ANA_ADD
RW
The value entered here is added as a basic offset to the value
read in by the analog input. The offset is also active in "B1"
mode.
EB4h
ANA_SOLL_SW
RW
Selects the dimension affected by the analog input.
0 -> Speed setpoint value (in "B1" mode only)
1 -> Parameter F29
2 -> Parameter F30
3 -> Maximum torque (M_SOLL_MAX, "S" command).
4 -> Position setpoint value in customer units
(A_LAGE_SOLL).
EF2h
ANA_FAK
RW
Scale factor (corresponding to parameter F9 on first analog
input).
EF4h
ANA_ADD
RW
Offset for value read in.
EF6h
ANA_OFS_1
RW
Hysteresis for second analog input. The value input here gives
the hysteresis for the second input in steps of 5 mV.
EF8h
ANA_STB
RW
Control byte for second analog input.
0 -> Analog input switched off
1 -> Value read written directly in the address input in the
memory location EFCh.
2 -> Value read in added to content of memory location,
whose address was input in the memory location EFCh.
EFCh
ANA_MEMO_1
RW
This is used to enter the address to be processed by the analog
input. The scaled value read in (with offset) is either stored di-
rectly at the address given here or added to the content (de-
pending on the control byte EF8h). With this function all memory
locations can be written. The user must check for a suitable
function.
830h
N_F_KNST
R
Over this speed, the unit runs with constant longitudinal current
for magnetization (Used for motors with large voltage drops in
the upper speed range and normally preset to a maximum
speed).
E7Eh
NIMPX_STB
RW
If this flag is set = 0, positioning takes place to the internal
transducer zero pulse (standard setting: decimal point illumi-
nated in diagnostics display). With a value of 255, positioning is
to an external transducer zero pulse.
EAAh
SOFTRESET
RW
If this memory location is set at 255, the inverter executes a
RESET and re-initializes.
08Eh
STB_NR5367
RW
Content 00h -> Enable dialogue messages
Content Offh-> Disable dialogue messages, i.e. commands can
be sent to the frequency inverter but there is no acknowledg-
ment
200h
SWITCH
RW
Operating mode selection:
= 00h U/f- characteristic curve
= 01h Speed control
= 02h Position control
= 03h Synchronized position
= 04h Synchronized speed
8.3.2 Speed
control
Address
Name
RW
Explanation
710h
N_IST
R
Actual speed value in increments / (4
×
scan time)
78Ch
N_IST2
R
Actual speed value in increments / (4
×
scan time) at second
transducer input
214h
V_IST
R
Actual speed value in customer units
210h
N_SOLL
R
Speed setpoint value in increments / (4
×
scan time)
20Eh
N_SOLL_V
R
Speed setpoint value before ramp in increments / (4
×
scan
time)