VECTORDRIVE DSV 5444
Top technology in drive electronics
07.07.04 10:12
Dietz-electronic
page 25 of 60
6 List of parameters
F0
Rotor flow
Explanation
Caution, if this function is activated, the maximum torque is set ("S" command) and the I
2
×
dt
limit is set at the maximum value.
Adress
09Eh
R
FI-control menu
Parameter
Value range
min.
25
max. 1200
Resolution
1
Unit
Note
F
I
series
I
rated motor
d
0 50
=
×
×
×
sin
ϕ
(for standart motor)
Series: values should be taken from the table in the section
Appendix, Other information
sin
ϕ
: see section
Appendix, Conversion table for sin
ϕ
, cos
ϕ
und tan
ϕ
.
A more precise result can be achieved with measurement. For this, the motor voltage is
measured with a moving-iron instrument. The motor must run at half the rated speed. The
rotor flow F0 is now set so that the moving-iron instrument shows half the rated voltage. If the
voltage is too low, the rotor flow should be increased. If the voltage is too high, the rotor flow
should be reduced.
Extended anchoring adjustment range (delta connection with 87 Hz characteristic):
F
I
Serie
I
Nenn Motor
d
0 0 9
3 55
=
×
×
×
×
×
−
.
sin
ϕ
(I
motor rating
for 50 Hz operation (star connection))
F1
Max. speed for const. torque
Explanation
Maximum speed for constant torque.
Adress
0A2h
R
FI control menu
Parameter
Value range
min.
200
max. N_MAX
Resolution
1 rpm
unit
[rpm]
F2
Speed at safe commutation limit (synchronous speed)
Explanation
Speed at safe commutation limit
Address
0A4h
R
FU-control menu
Parameter
Value range
min.
500
max. N_MAX
Resolution
1 rpm
Unit
[rpm]
F3
PCG
Position control loop
Explanation
Position control loop gain in proportional range
Address
0A6h
R
FI control menu
Parameter
Value range
min.
10
max. 400
Resolution
1
Unit
F4
Target ramp
Position control loop
Explanation
Target ramp (number always less than Y1)
Address
0A8h
R
FI control menu
Parameter
Value range
min.
1
max. 4000
Resolution
Unit
F5
Speed (3rd -> 2nd root section)
Position control loop
Explanation
Maximum speed for 2nd root braking curve range
Address
0AAh
R
FI control menu
Parameter
Value range
min.
200
max. N_MAX_1
Resolution
Unit
F6
Int. time const. pos. cntrl
Position control loop
Explanation
Integration time constant of speed control in position control
Address
0B0h
R
FI control menu
Parameter
Value range
min.
8
max. 256
Resolution
Unit