VECTORDRIVE DSV 5445
Top technology in drive electronics
07.07.04 10:12
Dietz-electronic
page 26 of 60
F7
Gain for position cntrl.
Position control loop
Explanation
Gain of speed control loop in position control
Address
0B2h
R
FI control menu
Parameter
Value range
min.
100
max. 2000
Resolution
Unit
F8
Offset 1 for zero position
Position control loop
Explanation
Offset for zero position for F11 (in the same direction of rotation)
Address
0BAh
R
FI control menu
Parameter
Value range
min.
-32767
max. +32767
Resolution
Unit
F9
Factor for analog setpoint value
Speed control loop
Explanation
Standardization for analog setpoint value (ANA_FAKT)/Operating mode B1
Address
0BCh
R
FI control menu
Parameter1
Value range
min.
1
max. 4095
Resolution
1
Unit
F10
Speed distributor
Speed control loop
Explanation
Used in conjunction with parameter F22 (see Section
Setting parameters, Standardization
and
Number of transducer points
)
Address
0B4h
R
FI control menu
Parameter
Value range
min.
+ 1
max. 32767
Resolution
1
Unit
F11
reduz.Drehz.1f.Position
Position control loop
Explanation
Reduced positioning speed; positioning in the same direction as the machine is running
Address
0BEh
R
FI control menu
Parameter
Value range
min.
1
max. N_MAX
Resolution
1
Unit
F12
Ref. cycle speed
Position control loop
Explanation
Speed of reference cycle
Address
0C0h
R
FI control menu
Parameter
Value range
min.
-N_MAX max. +N_MAX
Resolution
1
Unit
F13
Speed tolerance SET/ACTUAL on
Speed control loop
Explanation
Maximum speed deviation (tolerance window) for setting the "Required = Actual" message
Address
0C2h
R
FI control menu
Parameter
Value range
min.
4
max. 500
Resolution
1
Unit
F14
Speed SET/ACTUAL scan on
Speed control loop
Explanation
F14
×
0.8 milliseconds (scan time) gives the period in which the speed must fall within the
tolerance window to set the message "Set = ACTUAL"
Address
0C4h
R
FI control menu
Parameter
Value range
min.
1
max. 400
Resolution
1
Unit
F15
Speed tolerance SET/ACTUAL off
Speed control loop
Explanation
Minimum speed deviation (tolerance window) for deleting the "Required = Actual" message
Address
0C6h
R
FI control menu
Parameter
Value range
min.
1
max. 1000
Resolution
1
Unit