62/ TROUBLESHOOTING
OPERATOR'S MANUAL
Dj SEED MANAGER® SE PLANTER MONITOR
BENCHMARK Series®
11001-1218-200112 Rev A
ERROR CODE E00
No Modules have been detected by the Console.
Probable Cause
1. Implement Harness not connected to Tractor Harness
2. Implement Harness not connected to First Module (on P1 or P2 line)
3. Harnessing cut and/or pinched
4. Defective Console or Defective Module
Corrective Action
1. Check tractor harness and implement harness connections
2. Check connection at P1 and bus harness to the first module. Reapply power to
the console. If E00 occurs again, the tractor harness, module, or console is
defective.
3. Locate the fault and repair wires by splicing, soldering, and sealing wires.
4. Contact DICKEY-john Technical Support. See inside, back cover of this manual
for phone number.
ERROR CODE E01
Too Many Modules are connected to either P1 line or P2 line.
Probable Cause
More than Four modules are connected to either P1 or P2 Bus lines on
Implement Harness.
Corrective Action
Distribute modules evenly between P1 and P2 bus lines
ERROR CODE E10
Too Few Seed Modules are Connected.
Probable Cause
1. Number of Seed Modules Configuration is incorrect.
2. Implement Harness not connected to all Seed Modules
3. Harnessing cut and/or pinched
4. Defective Module