OPERATOR'S MANUAL
ALARM/ 55
Dj SEED MANAGER® SE PLANTER MONITOR
BENCHMARK Series®
11001-1218-200112 Rev A
9. Shaft Speed Lo Limit Warning
This occurs when any shaft speed falls
below the value entered for Shaft Speed
Lo Limit in the SETUP MODE. The
alarm beeps for three (3) seconds and
the shaft speed sensor number and
actual shaft speed, in RPM, are dis-
played. If multiple shaft speed sensors
fall below the limit, the shaft speed
sensor numbers are displayed sequen-
tially, along with their respective shaft
speeds. Figure 61 shows a Shaft Speed
Lo Limit Warning on shaft speed sensor
three (3) with a shaft speed of 427 RPM.
10. Pressure Hi Limit Warning
This occurs when any pressure input
exceeds the value entered for Pressure
Hi Limit in the SETUP MODE. The
alarm beeps for three (3) seconds and
the pressure sensor number and actual
pressure, in oz/in
2
(kPa), are displayed.
If multiple pressure sensors exceed the
limit, the pressure sensor numbers are
displayed sequentially, along with their
respective pressures. Figure 62 shows a
Pressure Hi Limit Warning on pressure
sensor one (1) with a pressure of 18.2
oz/in
2
.
Figure 61
SHAFT SPEED LO LIMIT Warning Display
Figure 62
PRESSURE HI LIMIT Warning Display