42/ OPERATE
OPERATOR'S MANUAL
Dj SEED MANAGER® SE PLANTER MONITOR
BENCHMARK Series®
11001-1218-200112 Rev A
3. Population Select Row
Depressing the SELECT ROW switch
while in either Population Scan or
Population Min Avg Max freezes the
population display on the current row or
the implement average. Pressing the
SELECT ROW switch again, causes the
display to advance to the next valid
population row. Pressing the BACK
switch, will cause the display to return to
the previous valid population row.
Figure 45 shows a population of 157,400
seeds/acre on row twelve (12) while in
Population Select Row.
4. Seed Spacing
This is the calculated average spacing
between seeds in the furrow, in inches
(centimeters). The resolution is in 0.1
inches (centimeters). This function is
selected by pressing the OPERATE 1
switch until the SPACING message
appears on the display. The Seed
Spacing display has several different
modes based upon the Setup configura-
tion and the scan mode that is selected.
They are the same modes as in the
Population function. Figure 46 shows an
implement average seed spacing of 2.3
inches between seeds.
Figure 45
Population SELECT ROW Display
Figure 46
Seed spacing average Display