OPERATOR'S MANUAL
SETUP/ 29
Dj SEED MANAGER® SE PLANTER MONITOR
BENCHMARK Series®
11001-1218-200112 Rev A
16. Fan Speed Sensor Lo Limit
This constant is the lowest Fan Speed
(RPM) allowed before sounding a
warning alarm. The Hi and Lo warning
limits are accessible only if the Number
of Fan Speed Sensors has a value other
than 0. The warning is enabled or
disabled by selecting the ON or OFF
message. Use the SELECT switch to
advance one step to the right of the right
most digit, then press the SET switch to
toggle between ON and OFF. Figure 24
shows a Lo limit of 25 RPM with the
warning disabled.
17. Number of Shaft Speed
Sensors
This is the actual number of Shaft Speed
Sensors that are connected to a Shaft
Speed Module on the system. For each
Shaft Speed Sensor that is configured
here, there will be an operate screen
generated. Shaft Speed Sensors are not
Self-Tested and will not generate any
error codes except for operational error
codes for Hi and Lo Limit warnings.
Figure 25 shows a configuration of three
(3) Shaft Speed Sensors.
Figure 24
Lo Limit Fan Speed Display
Figure 25
Shaft Speed Sensor Display