TEST AND AJUSTMENT MANUAL
49-TPOSE-PSC-EN02
13
4.3.15. Kabel Cash Register Protocol
Protocol
Cash Register
Scales
S
X
WE
X
(D
3
zD
4
) ó (D
3
uD
4
)
S
X
WWW.WWWxE
X
D
3
zD
4
Where:
S
X
:
0x02h
z:
0x7Ah
E
X
:
0x03h
u:
0x75h
D
3
:
0x13h
W:
0x57h
D
4
:
0x14h
WWW.WWW:
6 digits for WEIGHT.
.:
0x2Eh
4.3.16. Nci Cash Register Protocol
Protocol
Cash Register
Scales
1) Weight request
W C
R
L
F
xx.xxx Kg C
R
L
F
S
H
C
R
E
X
2) Status request
S C
R
L
F
S
H
C
R
E
X
3) Zero setting of the scale
Z C
R
L
F
S
H
C
R
E
X
4) Command unknown
In case of not sending any of the previous commands, the scale
answer “Command unknow”
L
F
? C
R
E
X
Were :
W:
0x57h
L
F
:
0x0Ah
S:
0x53h
E
X
:
0x03h
Z:
0x5Ah
S
H
:
0x01h
?:
0x3Fh
xxxxx:
5 digits for WEIGHT
C
R
:
0x0Dh
Kg:
0x4Bh y 0x47h
.:
0x2Eh Decimal point