3.
TEST
The test functions permit the user to check all of the important elements of the scale in order to assure that
they function correctly; or in the case of a malfunction, find the faulty element quickly. The scale must be
turned off to leave test mode.
3.1. ENTERING TEST MODE.
When the scale is turned on, a segment test is run showing a count down from 9 to 0.
To enter test mode,
press:
and
simultaneously before 0 is reached. Backlighting is on while the equipment is in mode
test.
The scale will show hyphens in all the display’s digits, followed by the following information.
1. The weight value in grams is shown in the weight display.
2. The zero weight value in internal divisions is shown in the price per kilogram display. This value
is accompanied by a hyphen, which is in the center segment if the value is in the limits set when
the scale was adjusted, or in the upper or lower segments if the value is greater or lesser than the
limits respectively.
3. The weight value in internal divisions is shown in the amount display.
3.2. DISPLAY TEST.
This is for checking that there are no visualisation problems. In test mode, press
and then keep
,
pressed to view all segments, until
is released.
Press
to exit.
3.3. KEYBOARD TEST.
This is for checking that all the keys are working.
During countdown, press each key. The countdown should pause every time a key is pressed, which will
indicate that the pressed key has been received.