background image

TEST AND AJUSTMENT MANUAL

49-TPOSE-PSC-EN02

11

5.7.9. 

Alfa Cash Register Protocol

Protocol

Cash Register

Scales

SWWW.WWWC

R

L

F

Where:

S:

Sign.

+: 0x2Bh
-: 0x2Dh

WWWWWW:

 

6 digits for WEIGHT.

.:

0x2Eh

C

R

:

 0x0Dh

L

F

:

 0x0Ah

4.3.10. Samsung-Spain Cash Register Protocol

Protocol

Cash Register

Scales

          

            $

                    WW.WWWC

R

Where:

$ :

0x24h

WWWWWW :

6 digits for WEIGHT.

.

 

:

0x2Eh

C

R

 :

0x0Dh

4.3.11. Samsung Portugal Cash Register Protocol

Protocol

Cash Register

Scales

             WC

r

             L

F

WW.WWWKGC

R

L

F

S00C

R

E

T

Where:

W:

0X57H, Weight request.

C

R

:

0x0Dh

L

F

:

0x0Ah

WWWWWW:

5 digits for WEIGHT.

.:

0x2E. Decimal point.

S:

0x53h. Weight status.

00:

0x30h, 0x30h. Whether correct weight status is activated.

KG:

0x4Bh y 0x47h

E

TX

:

0x03h

4.3.12. Uniprox / Bmc Ps 2000 Cash Register Protocol

Protocol

Cash Register

Scales

                    28PPPP0WWWWW0C

R

L

F

Where:

0:

0x30h

2 :

0x32h

8 :

0x38h

PPPP :

PLU Code

C

R

:

0x0Dh

WWWWW :

5 digits for WEIGHT.

L

F

:

0x0Ah

Note:

 the WEIGHT-PRICE-SUM is not a protocol for the scales. WEIGHT-PLU CODE

is, however, a protocol and therefore the keys in all the other protocols can be used to
enter the product price, and thus calculate the sum. In this protocol, the PLU code to be
sent to the cash register is determined. The row for the sum is cancelled in this protocol.

Summary of Contents for POS-SCANNER

Page 1: ...TEST AND ADJUSTMENT MANUAL POS SCANNER Ref 49 TPOSE PSC EN02...

Page 2: ......

Page 3: ...ING OF COMMUNICATIONS 14 5 4 1 Communication characteristics 14 5 5 COMMUNICATION PROTOCOLS 14 5 5 1 Selection of Protocol 14 5 5 2 Characteristics of the protocols 7 5 5 3 Operation 7 5 6 INFORMATION...

Page 4: ......

Page 5: ...TEST AND AJUSTMENT MANUAL 49 TPOSE PSC EN02 1 1 ASSEMBLY...

Page 6: ...h two displays vendor and buyer including the connection cable between scale and display 3 Connection cable scale scanner Ref BB 5897 4 Screws 4 allen type n 4 screws 5 Communications cable wit PC or...

Page 7: ...TEST AND AJUSTMENT MANUAL 49 TPOSE PSC EN02 3 Once the kit is placed in the right position it must be screwed by means of the 4 allen screws...

Page 8: ...SC EN02 4 1 2 2 Leveling Once the kit has been screwed the scale must be leveled by means of the vial placed in the front of the scale To modify the leveling the legs of the scale must be turned Turn...

Page 9: ...and verify the right leveling of the plate by means of an external level To fix the levelling of the plate use the plate leveling screws Once the plate is leveled the position of the screws must be fi...

Page 10: ...ust be plugged in one side in the coonector marked as SCALE SCANNER of the scale and in the other side in the connector marked as AUX PORT of the scanner IMPORTANT This cable is polarised so there is...

Page 11: ...splay scale is supplied mounted and plugged in the displays the other side must be plugged in the connector marked as SCALE DISPLAY of the scale 2 3 MAINS SUPPLY CONNECTION The connection of the scann...

Page 12: ...lue in grams is shown in the weight display 2 The zero weight value in internal divisions is shown in the price per kilogram display This value is accompanied by a hyphen which is in the center segmen...

Page 13: ...CPU This key can be pressed by removing a security covered screw and inserting a pointed object in the hole The following may be programmed 4 1 COUNTRY PROGRAMMING This parameter is only used for con...

Page 14: ...NT This allows the adjustment to be modified according to the altitude at which the scale is to operate without carrying out a complete adjustment with calibrated weights Program a value between 0 and...

Page 15: ...ighing platform and wait a few seconds for the weight to stabilize Press the key to begin the weight adjustment The display will show lines of hyphens while the adjustment is being done This process w...

Page 16: ...HARGE The reference of the Telecharge cable is BB 5918 5 1 DESCRIPTION OF TELECHARGE CABLE BB 5918 5 2 CONNECTION FOR TELECHARGE The Telecharge cable Ref BB 5918 must be connected to the Telecharge co...

Page 17: ...EN02 13 5 3 COMMUNICATIONS The cable to connect the scale to PC or POS has the reference BB 5896 and it must be plugged in the connector marked as SCALE COM of the scale L Never use a communications...

Page 18: ...d 12 19200 7 1 Even 32 1200 8 1 No 13 19200 7 1 Odd 33 1200 8 1 Even 14 19200 7 2 Even 34 1200 8 1 Odd 15 19200 7 2 Odd 35 1200 8 2 No 16 4800 8 1 No 36 1200 7 1 Even 17 4800 8 1 Even 37 1200 7 1 Odd...

Page 19: ...5 3 Operation Having configured the type of device with which communication is to be established simply effect the desired operation from the corresponding PC and the scales will automatically send t...

Page 20: ...06h 01 0x30 y 0x31h EC 0x1Bh EX 0x03h WWWWW 5 digits for the WEIGHT PPPPP 5 digits for the PRICE IIIIII 6 digits for the SUM 5 7 2 Tpv Casio Ce Protocol Protocol Cash register Scales SX AK 1PPPPPCRLF...

Page 21: ...WWWWWEIIIIIICCRLF Where 98 0x38h y 0x39h PPPPP 5 digits for the price C Checksum logical sum XOR of all previous characters CR 0x0Dh LF 0x0Ah 99 0x39h y 0x39h S Weight status S 0x30h Correct S 0x31h E...

Page 22: ...0Dh LF 0x0Ah 5 7 7 Apollo Samsung Poland Posnet Poland Cash Register Protocol Protocol Cash register Scales Eq AK D1 SHSxSWWW WWWkgBccExET Where Eq 0x05h AK 0x06h D1 0x11h SH 0x01h SX 0x02h S Weight s...

Page 23: ...x0Ah WWWWWW 5 digits for WEIGHT 0x2E Decimal point S 0x53h Weight status 00 0x30h 0x30h Whether correct weight status is activated KG 0x4Bh y 0x47h ETX 0x03h 4 3 12 Uniprox Bmc Ps 2000 Cash Register P...

Page 24: ...PPECEX Set 2 Cash Register Scales ETSX03ECPPPPPPECTTTTEX Set 3 Cash Register Scales ETSX05ECPPPPPPECTTTTECMMMMMMMMMMMMMEX Using the different heading the protocol is developed in the same way for all...

Page 25: ...0x2Eh 4 3 16 Nci Cash Register Protocol Protocol Cash Register Scales 1 Weight request W CR LF xx xxx Kg CR LF SH CR EX 2 Status request S CR LF SH CR EX 3 Zero setting of the scale Z CR LF SH CR EX 4...

Page 26: ......

Page 27: ...NT MANUAL 49 TPOSE PSC EN02 17 True copy of the manual deposited with notified body N 317 The information in this manual may be modified by the manufacturer without prior notice Ref 49 TPOSE PSC EN02...

Page 28: ......

Reviews: